How to fix clogged supply air filter in Komfovent Fan?
- TTeresa BoothAug 19, 2025
If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
How to fix clogged supply air filter in Komfovent Fan?
If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
How to fix clogged exhaust air filter in Komfovent Fan?
If the exhaust air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
What to do if supply air temperature sensor is not connected or broken down in Komfovent Fan?
If the supply air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if exhaust air temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 2000VW-EC Fan?
If the exhaust air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if outdoor temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 2000VW-EC Fan?
If the outdoor temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if plate heat exchanger temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 2000VW-EC?
If the plate heat exchanger temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
How to reset electric heater overheating protection on Komfovent Fan?
If the electric heater overheating protection is on in your Komfovent Fan, you can restore protection by pressing the “RESET” button located on the heater.
What to do if supply air temperature dropped lower allowable level in Komfovent KOMPAKT REGO 2000VW-EC Fan?
If the supply air temperature dropped lower than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
What to do if supply air temperature is higher allowable level in Komfovent Fan?
If the supply air temperature is higher than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
What to do if heater is disconnected due to low air flow in Komfovent KOMPAKT REGO 2000VW-EC?
If the heater is disconnected due to low air flow in your Komfovent Fan, the protection restores automatically when the heater cools down. It is recommended to increase the ventilation intensity level.
Instructions for connecting the unit to the appropriate electrical power supply, including earthing.
Wiring diagrams for connecting external components like control panels and sensors to connection boards.
Steps for installing the control panel in a suitable location and connecting it to the unit.
Guide to configuring programmable settings like operation modes, air volume control, and ventilation levels.
A table detailing common unit failures, their possible causes, and elimination steps.