KOMPAKT
REGO RECU OTK
Montavimo ir eksploatavimo instrukcija 3
Installation and Operation Manual 31
Инструкция по эксплуатации и монтажу 59
LT
EN
RU

Table of Contents

Questions and Answers

  • A
    Annette MillerAug 19, 2025
    How to fix clogged supply air filter in Komfovent Fan?
    • C
      charles42Aug 19, 2025
      If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
  • M
    marymunozAug 21, 2025
    How to fix clogged exhaust air filter in Komfovent KOMPAKT RECU 400VE-EC?
    • A
      Anne BeltranAug 22, 2025
      If the exhaust air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
  • C
    Chad AdamsAug 25, 2025
    What to do if supply air temperature sensor is not connected or broken down in Komfovent Fan?
    • B
      bjonesAug 25, 2025
      If the supply air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
  • S
    sarah91Aug 26, 2025
    What to do if exhaust air temperature sensor is not connected or broken down in Komfovent KOMPAKT RECU 400VE-EC Fan?
    • E
      elizabeth34Aug 26, 2025
      If the exhaust air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
  • R
    Rita SmithAug 28, 2025
    What to do if outdoor temperature sensor is not connected or broken down in Komfovent KOMPAKT RECU 400VE-EC?
    • U
      ugomezAug 28, 2025
      If the outdoor temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
  • P
    Phillip GarciaAug 30, 2025
    What to do if plate heat exchanger temperature sensor is not connected or broken down in Komfovent KOMPAKT RECU 400VE-EC Fan?
    • J
      jhernandezAug 30, 2025
      If the plate heat exchanger temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
  • L
    lisa86Sep 1, 2025
    How to reset electric heater overheating protection on Komfovent KOMPAKT RECU 400VE-EC?
    • M
      Matthew PatrickSep 1, 2025
      If the electric heater overheating protection is on in your Komfovent Fan, you can restore protection by pressing the “RESET” button located on the heater.
  • G
    Gloria LeonSep 3, 2025
    What to do if supply air temperature dropped lower allowable level in Komfovent KOMPAKT RECU 400VE-EC Fan?
    • T
      Tiffany VillarrealSep 3, 2025
      If the supply air temperature dropped lower than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
  • J
    Jessica WallSep 5, 2025
    What to do if supply air temperature is higher allowable level in Komfovent KOMPAKT RECU 400VE-EC Fan?
    • N
      Nicole BowmanSep 6, 2025
      If the supply air temperature is higher than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
  • E
    Emily LambertSep 7, 2025
    What to do if heater is disconnected due to low air flow in Komfovent KOMPAKT RECU 400VE-EC Fan?
    • E
      Eric PowellSep 8, 2025
      If the heater is disconnected due to low air flow in your Komfovent Fan, the protection restores automatically when the heater cools down. It is recommended to increase the ventilation intensity level.

Summary

1. TRANSPORTATION

4. MAINTENANCE

Routine Maintenance Schedule

Recommends performing routine maintenance 3-4 times per year on the REGO/RECU/OTK unit.

6. ELECTRICAL INSTALLATION MANUAL

6.2. Electric Power Supply

Guidelines for connecting the unit to electrical power, including voltage types and earthing.

6.3. External Elements Connection

Diagrams and instructions for connecting external elements to unit connection boards.

6.5. Control Panel Installation

Guidelines for installing the control panel, including connection and mounting requirements.

7. OPERATION MANUAL

7.1. Unit Control System

Overview of the control system, components, and control panel functions.

7.6. Programmable Settings

Detailed guide to programmable settings, including operation modes and air volume control.

7.9. Troubleshooting

Control Panel Failure Indications

Table detailing error messages, causes, and solutions for unit failures displayed on the control panel.

8. SAFETY REQUIREMENTS

General Safety Precautions

Essential safety measures including trained personnel, PPE, electrical compliance, and unit disconnection.

Komfovent KOMPAKT RECU 400VE-EC Specifications

General IconGeneral
Airflow rate400 m³/h
Heat recovery efficiencyUp to 92%
Heat exchanger typeCounterflow
Fan typeEC
Power supply230V/50Hz
Heat recovery efficiency (max)92%
Noise level45 dB
Noise level (max)50 dB
Filter classG4