How to fix clogged supply air filter in Komfovent KOMPAKT REGO 3000VW-EC?
- JJon HughesAug 19, 2025
If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
How to fix clogged supply air filter in Komfovent KOMPAKT REGO 3000VW-EC?
If the supply air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
How to fix clogged exhaust air filter in Komfovent KOMPAKT REGO 3000VW-EC?
If the exhaust air filter is clogged in your Komfovent Fan, you should turn the unit off and then replace the filter.
What to do if supply air temperature sensor is not connected or broken down in Komfovent Fan?
If the supply air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if exhaust air temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 3000VW-EC Fan?
If the exhaust air temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if outdoor temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 3000VW-EC?
If the outdoor temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
What to do if plate heat exchanger temperature sensor is not connected or broken down in Komfovent KOMPAKT REGO 3000VW-EC Fan?
If the plate heat exchanger temperature sensor is not connected or broken down in your Komfovent Fan, check the sensor connections or replace the sensor.
How to reset electric heater overheating protection on Komfovent KOMPAKT REGO 3000VW-EC Fan?
If the electric heater overheating protection is on in your Komfovent Fan, you can restore protection by pressing the “RESET” button located on the heater.
What to do if supply air temperature dropped lower allowable level in Komfovent Fan?
If the supply air temperature dropped lower than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
What to do if supply air temperature is higher allowable level in Komfovent KOMPAKT REGO 3000VW-EC Fan?
If the supply air temperature is higher than the allowable level in your Komfovent Fan, check the program settings, unit heat exchanger, and heater operation.
What to do if heater is disconnected due to low air flow in Komfovent KOMPAKT REGO 3000VW-EC?
If the heater is disconnected due to low air flow in your Komfovent Fan, the protection restores automatically when the heater cools down. It is recommended to increase the ventilation intensity level.
Covers checks for heat exchangers and fans to ensure optimal performance and longevity.
Details on connecting the unit to the main power supply, including voltage requirements and earthing.
Guide to connecting external components like sensors and actuators to the unit's connection boards.
Procedure for starting and stopping the air handling unit using the control panel.
Identifies common failures, their causes, and recommended elimination steps based on control panel messages.