L
lindsay40Aug 25, 2025
What to do if conveying stopped but Kongskilde Blower continues to run?
- CcfordAug 25, 2025
If the conveying has stopped but the Kongskilde Blower continues to run, it could be due to a pipe blockage or the rotary valve rotor being blocked by impurities in the material. First, close the intake shutter at the feed to see whether the blower itself is able to clear the system. If this doesn't work, you'll need to dismantle and empty the piping. Also, remove any impurities blocking the rotary valve rotor and check if the rotor has been damaged.