SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using the instrument.
Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock.
A
G
M
G
P
K
Printed in Japan9242-4889-11
©2002 KONICA MINOLTA SENSING, INC.
8
CHROMA METER
CR
-400/410
CR-400
CR-410
Units : mm
217
40.2
32
100
255
73
Data Processor DP-400
Measuring Head CR-400 Measuring Head CR-410
DimensionsSpecifications
Color Data Software CM-S100w
SpectraMagic
TM
NX
CR-400 Utility Software
CR-S4w
White Calibration Plate
CR-A43
White Calibration Plate
CR-A44
Protective Cap
CR-A72
Protective Cap
CR-A104
RS-232C Cable
CR-A101(Head-DP)
RS-232C Cable
CR-A102(for PC)
AC Adapter AC-A17
AC Adapter AC-A23(for Korea)
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Hard Case
CR-A103
Roll Paper (one roll)
Roll Paper
DP-A22(five rolls)
4 AA Size Batteries
4 AAA Size Batteries
Glass Light-Projection Tube
CR-A33a/f
Light-Projection Tube
CR-A33c/d
Glass Light-Projection Tube
CR-A33e
Granular-Materials Attachment
CR-A50
Pivoting Base
CR-A12
Color Tiles
Standard accessory
Optional accessory
M
e
a
s
u
r
i
n
g
H
e
a
d
C
R
-
4
0
0
M
e
a
s
u
r
i
n
g
H
e
a
d
C
R
-
4
1
0
D
a
t
a
P
r
o
c
e
sso
r
D
P
-
4
0
0
Standard/Optional
accessories
CR-400 Utility Software CR-S4w
To take measurements or change the
measurement parameters of the CR-400/410
Series, you can control the unit with a PC.
Measurement data can be transferred directly
to a Microsoft Excel
®
file by means of the OLE
function.
(Excel
®
97/2000/2002 is required to use the Excel
®
transfer function.)
Calibration data and color-difference
reference color data can be uploaded or
modified.
System requirements
OS Windows
®
98/2000/XP
CPU Pentium
®
166MHz or higher
Memory 32MB or higher
Hard disk 100MB or more free space
Display resolution
VGA (640× 480) or higher
System requirements
OS Windows
®
2000 Professional SP4,
Windows
®
XP Professional SP2
CPU Pentium
®
III 600 MHz or higher
Memory 128 MB (256 MB recommended)
Hard disk 450 MB of available disk space
Display
Graphic card capable of displaying 1024 x 768/High Color (16-bit)
Other CD-ROM drive (required for installation)
One free USB port or printer port (for protection key)
One free serial port (for instrument)
Internet Explorer Ver. 5.01 or later
Granular-Materials Attachment
CR-A50
With the Granular-Materials Attachment
CR-A50, the color of powders, pastes,
grains, and other granular substances can
be easily and accurately measured.
Glass Light-Projection Tube
CR-A33f (For CR-400) and CR-A33e (For CR-410)
Glass Light-Projection Tube CR-A33f and CR-A33e
have a glass plate at the tip and can be used for
measuring wet surfaces or for ensuring that materials
such as textiles are flat during measurements.
Pivoting Base CR-A12 (For CR-400)
Attaching the Pivoting Base CR-A12 to the
Measuring head of the CR-400 ensures
greater stability and accuracy in measurements
Light-Projection Tube CR-A33c is also included.
63 102 63 102
67.5
244
32
Name Data Processor
Model DP-400
Display range Y : 0.01 to 160.00% (reflectance)
Measurement time
2
1 Seconds.
Minimum measurement interval
2
3 Seconds.
Battery performance Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
Illuminants C, D65
Display Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
Tolerance judgment
2
Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Color space/ XYZ, Y x y, L
a
b
, Hunter Lab, L
C
h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
colorimetric data LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six registered in the Measuring Head can be used)
Languages Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
Storable data sets Max. 2000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Color difference target colors
2
Only for the operating function (100 pieces of data when the measuring head is connected; input of
measurement values or numeric) (independent of page function)
Calibration channels
2
Only for the operating function (20 channels when the measuring head is connected)
(ch00: white calibration; ch01 to ch19: user calibration)
Page function 100 pages
Display Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384 dot line thermal printer (
can also print graphs
) Automatically prints out all measurement results (
can be set not to print
)
Statistical function Maximum, minimum, average, and standard deviation
Automatic measurement
2
Date and time display: year, month, day, hour, minute
Timer: 3seconds. to 99 minutes.
(Some measurement modes require more than 3 seconds.)
Interface RS-232C compliant Baud rate (bps) : 19200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the measurement head
Power source 4 AA size alkaline or Ni-MH batteries,
AC adapter (AC-A17) AC120V 50-60Hz 0.4A (for N.America and Japan)
AC230V 50-60Hz 0.4A (for worldwide except N.America)
Size 100(W) x 73(H) x 255(D)mm
Weight Approx. 600g (not including batteries and paper)
Operating temperature/ 0 to 40
°C
, relative humidity 85% or less (at 35
°C)
with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation
Storage temperature/humidity range
-20 to 40
°C
, relative humidity 85% or less (at 35
°C)
with no condensation
Other User calibration function (multi-calibration/manual calibration)
2, Measurements for automatic average
function, Print ON/OFF function. CR-400 measurement data import function
2, All color space print ON/OFF
function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display
color limit function, Remote mode (stored data output), Character input function (alphanumeric)
2 indicates that part of or all functions are not available when the measurement head is not connected.
Name Chroma Meter Measuring Head
Model CR-400 Head CR-410Head
Illuminating/viewing system
d/0 (Diffuse illumination/0
°
viewing angle)
Wide-area illumination/0° viewing angle
(Specular component included) (Specular component included)
Detector Silicone photo cells (6)
Display range Y: 0.01 to 160.00% (reflectance)
Light source Pulsed xenon lamp
Measurement time 1 seconds.
Minimum measurement interval
3 seconds.
Battery performance Approx. 800 measurements
(when using batteries under company testing Konica Minolta's conditions)
Measurement/illumination area
φ8/φ11 φ50/φ53
Repeatability Within E*ab0.07 standard deviation (when the white calibration plate
is measured 30 times at intervals of 10 seconds)
Inter instrument E*ab: within 0.6 E*ab: within 0.8
agreement Average of 12 BCRA series II colors
Observer 2 degrees Closely matches CIE 1931 Standard Observers: ( x2λ, yλ, zλ)
Illuminant
1 C, D65
Display
1 Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgment
1 Color difference tolerance (box tolerance and elliptical tolerance)
Color space/
XYZ, Y x y, L
a
b
, Hunter Lab, L
C
h, Munsell (only illuminant C), CMC(l:c), CIE1994, Lab99,
colorimetric data
LCh99, CIE2000, CIE WI•Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages Operating keys : English
LCD : English (default)
(LCD : German, French, Italian, Spanish, Japanese) *1
Storable data sets 1000 (measuring head and data processor save different data)
Color difference target colors
100
Calibration channels
*1 20 channels (ch00 : white calibration, ch01 to ch19 : user calibration)
Display
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface RS-232C compliant (for data processor/PC)
* Baud rate : 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
Power source 4 AAA size alkaline or Ni-MH batteries,
AC adapter (AC-A17) AC120V 50-60Hz 0.4A (for N.America and Japan)
AC230V 50-60Hz 0.4A (for worldwide except N.America)
Size
102(W) x 217(H) x 63(D)mm 102(W) x 244(H) x 63(D)mm
Weight Approx. 550g Approx. 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operating temperature/
0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation
Storage temperature/humidity range
-20 to 40°C, relative humidity 85% or less (at 35°C) with no condensation
Other LCD back light ON/OFF function (when ON, back light stays ON for 30
seconds after last key or measurement operation)
1 indicates when connected to the Data Processor or when not set using the Data Processor or the optional software,
that some of the function are not available when the measuring head is not connected.
Optional Accessories
System Diagram
Standard accessory
Optional accessory
CR-410
CR-400
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Protective Cap
CR-A72
Protective Cap
CR-A104
AAA Size
Battery (x4)
Roll Paper
DP-A22
(five rolls)
RS232C Cable(for PC)
CR-A102
PC (commercially available)
AA Size
Battery (x4)
RS232C Cable
(Head-DP)
CR-A101
White Calibration
Plate
CR-A43
Glass Light
Projection Tube
CR-A33a
(with convex glass)
Glass Light-Projection
Tube
CR-A33e
Glass Light
Projection Tube
CR-A33f
(with concave glass)
Light
Projection Tube
CR-A33c
(no disc)
Pivoting Base
CR-A12
(includes CR-A33c)
Light
Projection Tube
CR-A33d
(with φ22mm disc)
Granular-Materials
Attachment
CR-A50
Color Tiles
White Calibration
Plate
CR-A44
AC Adapter
AC-A17
AC Adapter
AC-A23
(for Korea)
DP-400
Measuring Head
Data Processor
CR-400 Utility
Software
CR-S4w
Hard Case
CR-A103
(includes one Roll Paper)
Specifications are subject to change without notice.
SpectraMagic
TM
NX
CM-S100w
SpectraMagic
TM
NX
Supports Windows
®
2000/XP
(
optional
)
Specifications
SpectraMagic
TM
NX enables you to perform
comprehensive color inspection and analysis of
incoming raw materials, in process production,
and outbound color critical goods and materials
in virtually any industry. With SpectraMagic
TM
NX
you can insert digital images with measured data.
Measure samples in any of 8 universally accepted
color spaces. Select from 15 illuminants, and up
to 40 indices to determine specific color and
appearance properties, such as brightness, haze,
yellowness, opacity and strength. You can even
configure up to 3 customized color equations.
Reports range from simple Pass/Fail to trend
charts, histograms, color plots, and spectral
graphs. SpectraMagic
TM
NX comes with predefined
templates using skin technology, or you can
create your own templates. For illustrations and
explanations to understanding color and color
measurement technology, there is a link to
Konica Minolta's well known and respected
“Precise Color Communication”.
Color space
Index
Color
difference
equation
Observer
Illuminants
Graph
display
L*a*b*, L*C*h, Lab99, LCh99, XYZ, Hunter
Lab, Yxy, L*u'v', L*u*v*, Munsell, and their
color differences (excluding Munsell)
WI (CIE 1982, ASTM E313-73, Hunter,
Berger, Taube, Stensby, Ganz), Tint(Ganz),
YI (ASTM D1925-70, ASTM E313-73,
ASTM E313-96, DIN6167), WB (B ASTM
E313-73), Standard Depth (ISO 105.A06),
R
XRYRZ, Gray scale(ISO 105.A05)
E*ab (CIE 1976), E*94 (CIE 1994), E00
(CIE 2000), E
99 (DIN99), E (Hunter),
CMC (I:c), FMC-2, NBS 100, NBS 200
2 degree
C, D65
L*a*b* absolute value, L*a*b* (color
difference distribution), Hunter Lab
absolute value, Hunter Lab (color
difference distribution), Trend chart and
histogram of each color space and color
difference equation, Pseudo Color display

Other manuals for Konica Minolta CR-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Konica Minolta CR-400 and is the answer not in the manual?

Konica Minolta CR-400 Specifications

CR-400 Head

Operating Environment IconOperating Environment
operating temperature range0 to 40°C
operating humidity range85% or less (at 35°C) with no condensation
storage temperature range-20 to 40°C
Power IconPower
battery type4 AAA size alkaline or Ni-MH batteries
AC adapter inputAC120V 50-60Hz 0.4A (for N.America and Japan), AC230V 50-60Hz 0.4A (for worldwide except N.America)
Weight and Dimensions IconWeight and Dimensions
dimensions102(W) x 217(H) x 63(D) mm
weight550 g
measurement/illumination areaφ8/φ11

CR-410 Head

Operating Environment IconOperating Environment
operating temperature range0 to 40°C
operating humidity range85% or less (at 35°C) with no condensation
storage temperature range-20 to 40°C
Power IconPower
battery type4 AAA size alkaline or Ni-MH batteries
AC adapter inputAC120V 50-60Hz 0.4A (for N.America and Japan), AC230V 50-60Hz 0.4A (for worldwide except N.America)
Weight and Dimensions IconWeight and Dimensions
dimensions102(W) x 244(H) x 63(D) mm
weight570 g
measurement/illumination areaφ50/φ53

DP-400

Operating Environment IconOperating Environment
operating temperature range0 to 40°C
operating humidity range85% or less (at 35°C) with no condensation
storage temperature range-20 to 40°C
Power IconPower
battery type4 AA size alkaline or Ni-MH batteries
AC adapter inputAC120V 50-60Hz 0.4A (for N.America and Japan), AC230V 50-60Hz 0.4A (for worldwide except N.America)
Weight and Dimensions IconWeight and Dimensions
dimensions100(W) x 73(H) x 255(D) mm
weight600 g
storable data setsMax. 2000 pieces of data