Konica Minolta CL-70F - User Manual

Konica Minolta CL-70F
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CRI Illuminance Meter
Please read the operating manual carefully to fully understand the features of this product
before use and keep it for future use. Keep the operating manual in a safe place.
CL-70F
Operating Manual

Table of Contents

Other manuals for Konica Minolta CL-70F

Questions and Answers

  • A
    Andrea ThomasAug 1, 2025
    Why are the measured values wrong on my Konica Minolta CL-70F Measuring Instruments?
    • H
      Hector SandovalAug 1, 2025
      If the measured values are incorrect on your Konica Minolta Measuring Instruments, ensure the Light Selection Ring is rotated until it clicks. Also, verify that the measuring mode is correct. In Cordless Flash Mode, the main flash's measurement may be inaccurate due to the pre-flash being measured first; disable the pre-flash function to resolve this.
  • J
    Johnathan ClarkeAug 11, 2025
    What to do if Konica Minolta CL-70F Measuring Instruments does not turn on?
    • C
      Cory JenkinsAug 11, 2025
      If your Konica Minolta Measuring Instruments do not turn on or display anything, try the following: First, press and hold the Power Button for at least one second. Next, check the batteries and replace them if necessary. Finally, wipe the batteries off with a dry cloth.
  • P
    Philip JonesAug 21, 2025
    Why the memory function cannot be used on Konica Minolta Measuring Instruments?
    • E
      ericsalasAug 21, 2025
      If the memory function on your Konica Minolta Measuring Instruments cannot be used, first cancel the differential measurement mode. Also, note that the memory can store up to 999 values; clear any unnecessary stored values before attempting to measure and memorize new data.

Summary

Safety Precautions

General Safety Warnings

Covers essential WARNING and CAUTION points for safe operation and product integrity.

Maintenance and Notices

Addresses specific warnings like PVC cable hazards and general maintenance guidelines.

Before Use and Basic Operations

Initial Setup and Power Management

Guides on attaching the strap, installing batteries, powering on/off, and checking battery status.

Interface Navigation and Input

Explains the screen layout, touch controls, icons, and data input methods.

Measurement Procedures

Setting Measurement Conditions

Covers selecting modes, exposure time, shutter speed, and display customization.

Performing Measurements

Details ambient light, flash measurements, monitor function, and error handling.

Meter Settings and Calibration

Configuring Preferences and Presets

Guides on customizing settings, editing presets, and viewing item specifications.

Dark Calibration

Procedure for calibrating the meter's sensor to ensure accurate readings.

Hardware Settings

Device Adjustments and Reset

Covers touch panel adjustment, user information editing, field of view, and factory reset.

Appendix

Glossary and Specifications

Provides definitions of technical terms and detailed specifications of the instrument.

Konica Minolta CL-70F Specifications

General IconGeneral
TypeColorimeter
Light SourcePulsed Xenon Lamp
Measuring TimeApprox. 1 second
Measurement AreaΦ8mm
Spectral ResponseCIE 1931 standard observer (2° field of view)
SensorSilicon Photodiode
Inter-Instrument AgreementΔE*ab 0.4 or less
DisplayLCD
InterfaceUSB 2.0
Power SupplyRechargeable Lithium-ion Battery
Storage Temperature-20 to 55°C (-4 to 131°F), noncondensing

Related product manuals