EasyManua.ls Logo

KONVEKTA KL60 - User Manual

KONVEKTA KL60
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Konvekta AG
Konvekta AGKonvekta AG
Konvekta AG
Am Nordbahnhof 5
34613 Schwalmstadt
Germany
+49 ( 0 ) 66 91 / 76 – 0
+49 ( 0 ) 66 91 / 76 - 200
Info@konvekta.com
www.konvekta.com
Operating Instru
Operating InstruOperating Instru
Operating Instruc
cc
ction
tiontion
tion
for KONVEKTA
for KONVEKTAfor KONVEKTA
for KONVEKTA
Air Conditi
Air ConditiAir Conditi
Air Conditio
oo
oning units
ning unitsning units
ning units
KL60
KL60 KL60
KL60
up to
up toup to
up to
KL85T
KL85T KL85T
KL85T
with control KS310
with control KS310with control KS310
with control KS310
R134a
R134aR134a
R134a
24 Volt DC
24 Volt DC24 Volt DC
24 Volt DC
Versions:
Versions:Versions:
Versions:
Recirculated Air
Fresh Air
Heating
ID#: B
ID#: BID#: B
ID#: BBA
BABA
BA-
--
-KL60T12AE
KL60T12AEKL60T12AE
KL60T12AE
Version: A01
Version: A01Version: A01
Version: A01

Other manuals for KONVEKTA KL60

Questions and Answers

  • I
    Isabella SilvaAug 18, 2025
    Why is there a loud noise at the compressor of my KONVEKTA KL60 Air Conditioner?
    • B
      Benjamin McdanielAug 18, 2025
      A loud noise at the compressor of your KONVEKTA Air Conditioner can be caused by a defective bearing at the compressor, in which case you should replace either the bearing or the entire compressor. Another possible cause is a slack V-belt, so check the V-belt at the compressor drive.
  • A
    Adam JensenAug 25, 2025
    Why is there a strong noise at the KONVEKTA Air Conditioner compressor?
    • A
      Abigail MillerAug 26, 2025
      If you notice a strong noise at the compressor of your KONVEKTA Air Conditioner, it could stem from a few reasons. First, check the V-belt at the compressor drive, as a slack V-belt can cause noise. Also, inspect the connections at the magnetic clutch. If the compressor isn't compressing properly, check the pressure at both the suction and pressure sides, and consider replacing the compressor. Lastly, a defect bearing on the compressor can cause noise, in which case you should replace the ball bearing or the entire compressor.
  • W
    William RichardsonAug 30, 2025
    Why is my KONVEKTA KL60 Air Conditioner compressor making a loud noise?
    • A
      Austin LewisAug 30, 2025
      A loud noise at the KONVEKTA Air Conditioner compressor could be due to a defective bearing, in which case you should replace either the bearing or the entire compressor. Alternatively, check the V-belt at the compressor drive, as a slack V-belt can also cause this issue.
  • W
    watsonjohnSep 6, 2025
    How to fix a strong noise at the KONVEKTA KL60 compressor?
    • D
      deanna90Sep 6, 2025
      If your KONVEKTA Air Conditioner compressor is making a strong noise, there are several potential causes. A slack V-belt could be the issue, so check the V-belt at the compressor drive. It could also be related to the magnetic clutch, so check the connections at the magnetic clutch. If the compressor isn't compressing, check the pressure at the suction and pressure side, and possibly exchange the compressor. A defect bearing on compressor can also cause noise, so replace the ball bearing or the complete compressor.
  • M
    Michael RoseSep 8, 2025
    What to do if the LED flashes on my KONVEKTA Air Conditioner?
    • Z
      Zachary AndersonSep 8, 2025
      If the LED is flashing on your KONVEKTA Air Conditioner, it could indicate several issues. It might be due to excess pressure caused by a high outside temperature; in this case, run the unit until the pressure stabilizes. Another possibility is a leakage in the A/C unit or a lack of refrigerant, requiring you to check for leakages and refill the refrigerant. Additionally, it could be due to low pressure caused by a clogged dryer (replace the dryer) or a clogged screen of the expansion valve (clean the screen and replace the dryer). Lastly, the compressor might not be compressing, in which case you should check the high and low pressure and replace the compressor if necessary.
  • C
    christensenmadelineSep 12, 2025
    How to fix loud noise at compressor of KONVEKTA Air Conditioner?
    • R
      Rebecca JohnsonSep 12, 2025
      Loud noises at the compressor of your KONVEKTA Air Conditioner can stem from a defective bearing, in which case you should replace either the bearing or the entire compressor. Another potential cause is a slack V-belt; therefore, check the V-belt at the compressor drive.
  • J
    Jessica JacksonNov 14, 2025
    What to do if my KONVEKTA KL60 is not running and the LED flashes?
    • D
      David DanielsNov 14, 2025
      If the KONVEKTA Air Conditioner is not running and the LED is flashing, several issues could be the cause. First, the thermostat might be open, so check the inside temperature and readjust the thermostat. Also, check the electrical connections at the switchboard in case they are disconnected. A defective relay could also be the problem, so check the relay and replace it if needed. The defrost thermostat might have switched off, in which case you should check the evaporator blower and replace it if necessary. If the outside temperature is too low, try switching on only the ventilation. Clean the evaporator coil with compressed air if it's dirty. If there's excess pressure, check the axial fans, fuses at the switchboard, and clean the condenser coil with compressed air. If the excess pressur...
  • B
    Benjamin WilliamsNov 20, 2025
    What to do if my KONVEKTA KL60 Air Conditioner is not running?
    • T
      Thomas HawkinsNov 20, 2025
      If your KONVEKTA Air Conditioner isn't running, there are several potential causes. It could be due to disconnected electric wiring, so check the wiring at the switch plate. A defective relay could also be the culprit; in this case, check the relay and replace it if needed. The defrosting thermostat might be cutting off, so inspect the evaporator blower and replace it if necessary. Other potential issues include low outside temperature (try switching to ventilation only), a dirty evaporator coil (clean it with compressed air), or high pressure (check axial fans, fuses, and clean the condenser coil). If the pressure is too high due to high outside temperature, let the unit run until the pressure stabilizes. Finally, a leak in the unit or low refrigerant could be the problem, so check for le...
  • A
    Allen MillerNov 26, 2025
    What to do if KONVEKTA Air Conditioner is not running and LED flashes up?
    • C
      cassandra09Nov 26, 2025
      If your KONVEKTA Air Conditioner isn't running and the LED is flashing, here are several things you can check: * Ensure the thermostat isn't open by checking the inside temperature and readjusting the thermostat. * Verify all electrical connections at the switchboard are secure. * Inspect the relay and replace it if it's defective. * Check the evaporator blower and replace it if necessary. * If the outside temperature is too low, switch to ventilation only to prevent icing. * Clean the evaporator coil with compressed air if it's dirty. * Address excess pressure by checking axial fans, fuses at the switchboard, and cleaning the condenser coil with compressed air. * If excess pressure is due to high outside temperature, let the unit run until the pressure stabilizes. * Che...
  • A
    Ashley BeckDec 3, 2025
    Why is my KONVEKTA Air Conditioner not running?

    Summary

    Introduction to KONVEKTA Air Conditioning Units

    General Information and Scope

    Overview of the manual's purpose, audience, and content for safe operation.

    Operating Instructions Details

    Unit Identification and Data Recording

    Fields for recording unit serial number, order number, and operation date for warranty.

    Technical Specifications

    Air Conditioning Unit Specifications

    Detailed technical data for KL60 to KL85T models including capacity, volume, and dimensions.

    Pressure Switch Settings

    Specifications for low and high-pressure switches, critical for system operation.

    Compressor Technical Data

    Technical details and important maintenance notes for compressors.

    Compressor and System Usage

    KVX40 Compressor Type Details

    Specific technical data, weight, and oil requirements for KVX40 compressor types.

    Determined Use of Air Conditioning Unit

    Defines the intended application and operating parameters for the AC unit.

    General AC Unit Information

    Explains normal operation, condensate drainage, and filter maintenance for optimal performance.

    Operating Conditions and Material Notes

    Guidelines on operating environments and material considerations to prevent corrosion.

    System Operation Overview

    Description of Control Display Symbols

    Explains various symbols and indicators on the driver and passenger displays for clear operation.

    Driver Seat Control Functions

    Air Distribution and Defrost Control (S1)

    Controls air direction to windshield and activates defrost function for visibility.

    Air Distribution Controls (S2, S3)

    Manages air flow distribution to the center and foot area for occupant comfort.

    Front Box A;C Activation (S4)

    Enables the front box air conditioning function, requiring compressor activation.

    Return Air Flap Operation (S5)

    Controls the air recirculation flap, switching to fresh air after 10 minutes.

    Blower Speed Adjustment (S6)

    Sets the front box blower speed in 7 stages, limited by ignition status.

    Air Delivery Temperature Adjustment (S7)

    Allows automatic or manual adjustment of air delivery temperature for desired comfort.

    Passenger Compartment Control Functions

    Evaporator Blower Speed Control (S8)

    Manually adjusts evaporator blower speed in 7 stages or infinitely variable in AUTO.

    Room Temperature Adjustment (S9)

    Sets desired temperature from 15-26°C, with AUTO defaulting to 23°C.

    Automatic System Control (S10)

    Activates/deactivates automatic control of heating, ventilation, and refrigeration.

    Reheat Function Activation (S11)

    Engages compressor to dehydrate air and maintains temperature with roof heating.

    ECO Mode and Compressor Control (S12)

    Manually stops the compressor; compressor is blocked in Reheat and AUTO modes.

    Additional Adjustments and Options

    Convector and Seat Heating Control (S13)

    Manages convector and driver's seat heating based on AUTO setting and room temperature.

    Display Mode and Ice Warning (S14)

    Switches display between time and outside temperature, with an ice warning function.

    Return Air Flap Manual Setting (S15)

    Manually sets the air flap to circulated air position, returning to fresh air after 10 min.

    Additional Heating Adjustment (S16)

    Prepares the convector control for additional heating operation.

    General Adjustments

    Time Programming and Adjustment

    Procedure for setting the current time and programming the heating system's start time.

    Additional Heating Start Time Programming

    Details on programming daily or specific day start times for the additional heating system.

    Maintenance and Service Procedures

    Scheduled Maintenance Periodicity

    Annual maintenance checks including leak detection, connections, and component inspection.

    Compressor Oil Change and Cleaning

    Guidelines for oil changes, frequency, and cleaning the oil suction strainer.

    Return Air Grid Cleaning

    Monthly or weekly cleaning instructions for the return air grid to ensure airflow.

    Condenser Coil Cleaning

    Recommendations for cleaning the condenser coil to prevent overpressure and system interruption.

    System Diagnostics and Testing

    Reading and Clearing Trouble Memory

    Instructions for accessing fault codes, displaying, and deleting them from the unit's memory.

    Self-Test Functionality

    Describes the unit's self-test sequence upon power application and sub-station behavior.

    Troubleshooting Common Issues

    Warranty, Disposal, and Revision

    General Warranty Conditions

    Information on applicable general warranty terms and conditions for KONVEKTA AG.

    Legal Waste Disposal Provisions

    Outlines regulations and responsibilities for the proper disposal of refrigerants and components.

    Document Modification History

    Records changes and updates made to the operating instructions over different versions.

    KONVEKTA KL60 Specifications