Operating instructions
for KONVEKTA
air conditioning units
StreamLine
SL700–SL800–SL850–SL900
with control KS600-CAN
R134a
24 Volt DC
ID#: BBA-KL7S012AB
Version: A02

Questions and Answers

  • Z
    zhangjamieAug 18, 2025
    What to do if KONVEKTA Air Conditioner is not running?
    • S
      Steven MoonAug 19, 2025
      What to do if your KONVEKTA Air Conditioner is not running? Here are a few things you can check: * First, make sure that the thermostat is properly set. * Second, check the electrical connections at the switchboard. * Third, inspect the relay and replace it if necessary. * Fourth, check the evaporator blower and replace it if necessary. Also, consider cleaning the evaporator coil with compressed air or checking the connections at the magnetic clutch. If none of these steps work, it may be necessary to have a professional inspect the unit for more serious issues like compressor problems or refrigerant leaks.
  • J
    johnatkinsAug 28, 2025
    How to fix loud noise at compressor in KONVEKTA Air Conditioner?
    • D
      Darryl MooreAug 28, 2025
      If you notice a loud noise at the compressor of your KONVEKTA Air Conditioner, it could be due to a defective bearing. In this case, you should replace either the bearing or the entire compressor. Another possible cause is a slack V-belt. Check the V-belt at the compressor drive to resolve this issue.
  • B
    Bryan Lopez Jr.Nov 8, 2025
    Why is my KONVEKTA StreamLine SL800 not running?
    • J
      Jason WoodNov 8, 2025
      If your KONVEKTA Air Conditioner isn't running, several factors could be the cause. It might be due to an open thermostat; in this case, check the inside temperature and readjust the thermostat. Another potential reason is a disconnected electrical connection; inspect the electrical connections at the switchboard. A defective relay could also be the culprit, so examine the relay and replace it if needed. If the defrost thermostat has switched off, check the evaporator blower and replace it if necessary. Low outside temperatures can cause icing of the evaporator, so switch to ventilation only. A dirty evaporator coil can also prevent the AC from running; clean it with compressed air. Problems with the magnetic clutch, such as loose connections, should be checked. If the compressor isn't com...

Summary

Introduction

Information on the operating instructions

1. Technical data

1.1. Compressor type KVX

Details on KVX compressor types, maintenance, and oil specifications for proper function.

2. Intended Use

2.1. Generally information for a;c unit

General operational guidance for the AC unit, including usage tips and warnings.

2.2. Operating Conditions

Defines the environmental and operational parameters for safe and effective AC unit use.

3. Operation

3.1. Operation panel; function of the keys

Explanation of the control panel layout, rotary knobs, and key functions for operating the AC.

3.2. Special functions of the KS600

Details on advanced KS600 control functions like SMOG mode, display changes, and keyboard lock.

4. Maintenance; Service

4.1. Troubleshooting

A guide to diagnosing and repairing common AC unit problems, including causes and recommended solutions.

5. Warranty Conditions

6. Waste disposal in accordance with legal provisions

7. History of modification

KONVEKTA StreamLine SL800 Specifications

General IconGeneral
BrandKONVEKTA
ModelStreamLine SL800
CategoryAir Conditioner
LanguageEnglish

Related product manuals