Operating Instructions
for KONVEKTA
Air Conditioning units
UL500 / UL700 / UL800
with Wabco control system
R134a
24 Volt DC
ID#: BBA-KL6U022AA
Version: A03

Questions and Answers

  • M
    Martin LeeAug 22, 2025
    Why is there a loud noise at the compressor of my KONVEKTA UL700 Air Conditioner?
    • S
      Sarah MunozAug 22, 2025
      Loud noises at the compressor of your KONVEKTA Air Conditioner can stem from a defective bearing. In this case, replace either the bearing or the entire compressor. Another potential cause is a slack V-belt, so make sure you check the V-belt at the compressor drive.
  • P
    piercerichardNov 5, 2025
    What to do if my KONVEKTA Air Conditioner is not running?
    • K
      Kevin GreenNov 5, 2025
      If your KONVEKTA Air Conditioner is not running, it could be due to several reasons. First, check the inside temperature and readjust the thermostat if it's open. Inspect the electric connections at the switchboard to ensure they are properly connected. A defective relay could also be the cause, so check and replace it if needed. If the defrost thermostat has switched off, examine the evaporator blower and replace it if necessary. If the outside temperature is too low, try switching on only the ventilation. Clean the evaporator coil with compressed air if it's dirty. Also, check the connections at the magnetic clutch. If the compressor isn't compressing, check the high and low pressure and replace the compressor if necessary. For excess pressure, check the axial fans, fuses at the switchbo...

Summary

Introduction

Information on Operating Instructions

Technical Data

Air Conditioner Specifications

Specific technical data for air conditioner units like refrigerant, voltage, power, and cooling capacity.

Compressor Information

Details related to compressor specifications and operational requirements.

Intended Use

Operating Conditions

Details environmental conditions and operational parameters for the unit.

Operation

Operation Panel and Key Functions

Overview of the control panel, including flap control, temperature, blower speed, and smog function.

Maintenance and Troubleshooting

Maintenance Instructions

Refers to specific maintenance documents and requires qualified staff for service.

Troubleshooting Guide

Lists common problems, their causes, and recommended repair actions by authorized service stations.

Warranty and Disposal

Warranty Conditions

States that current General Warranty Conditions KONVEKTA AG apply.

Waste Disposal Regulations

Details environmental regulations and legal provisions for waste management.