Operating instructions
for KONVEKTA
air conditioning units
StreamLine
SL700–SL800–SL850–SL900
with control KS600-CAN
R134a
24 Volt DC
ID#: BBA-KL7S012AB
Version: A02

Questions and Answers

  • W
    webbstephenAug 12, 2025
    What to do if KONVEKTA Air Conditioner is not running?
    • G
      Gregory LambertAug 12, 2025
      What to do if your KONVEKTA Air Conditioner is not running? Here are a few things you can check: * First, make sure that the thermostat is properly set. * Second, check the electrical connections at the switchboard. * Third, inspect the relay and replace it if necessary. * Fourth, check the evaporator blower and replace it if necessary. Also, consider cleaning the evaporator coil with compressed air or checking the connections at the magnetic clutch. If none of these steps work, it may be necessary to have a professional inspect the unit for more serious issues like compressor problems or refrigerant leaks.
  • K
    Kendra HolmesAug 22, 2025
    How to fix loud noise at compressor in KONVEKTA StreamLine SL700 Air Conditioner?
    • R
      Randy LeonAug 22, 2025
      If you notice a loud noise at the compressor of your KONVEKTA Air Conditioner, it could be due to a defective bearing. In this case, you should replace either the bearing or the entire compressor. Another possible cause is a slack V-belt. Check the V-belt at the compressor drive to resolve this issue.
  • E
    Eileen FlynnNov 1, 2025
    Why is my KONVEKTA StreamLine SL700 not running?
    • B
      Brandi BurnsNov 1, 2025
      If your KONVEKTA Air Conditioner isn't running, several factors could be the cause. It might be due to an open thermostat; in this case, check the inside temperature and readjust the thermostat. Another potential reason is a disconnected electrical connection; inspect the electrical connections at the switchboard. A defective relay could also be the culprit, so examine the relay and replace it if needed. If the defrost thermostat has switched off, check the evaporator blower and replace it if necessary. Low outside temperatures can cause icing of the evaporator, so switch to ventilation only. A dirty evaporator coil can also prevent the AC from running; clean it with compressed air. Problems with the magnetic clutch, such as loose connections, should be checked. If the compressor isn't com...

Summary

Technical Data

Compressor Type KVX

Details about KVX compressor types, weight, refrigerant oil, and magnetic clutch.

Intended Use

General Information for A;C Unit

Information on a/c unit operation, window/door closure, condensate, and air filters.

Operating Conditions

Notes on component materials and corrosion under aggressive environmental conditions.

Operation

Operation Panel and Key Functions

Overview and function of the control panel's rotary knobs and keys for unit operation.

Special Functions of KS600

Activation and usage of special functions like SMOG mode, function modes, and display settings.

Maintenance and Service

Troubleshooting

Common problems, their causes, and recommended repair actions by authorized service stations.

Warranty Conditions

Waste Disposal

History of Modification