Installation Instructions Section 2
8 Part Number 000012545 4/14
Maximum Breaker Size & Minimum Circuit Amperage Chart
Due to continuous improvements, this information is for reference only. Please refer to the ice machine serial number tag
to verify electrical data. Serial tag information overrides information listed on this page.
Ice Machine
Voltage/Phase/
Cycle
Air-Cooled Water-Cooled Remote
Maximum Fuse/
Circuit Breaker
Minimum
Circuit Amps
Maximum Fuse/
Circuit Breaker
Minimum
Circuit Amps
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
K0250
115/1/60 15 9.44 15 N/A N/A N/A
230/1/50 15 4.5 15 N/A N/A N/A
230/1/60 15 4.7 15 N/A N/A N/A
K0350
115/1/60 15 12.1 15 11.4 N/A N/A
230/1/50 15 6.3 15 5.9 N/A N/A
230/1/60 15 6.2 15 5.8 N/A N/A
K0420
115/1/60 15 11.3 15 10.6 N/A N/A
230/1/50 15 6.2 15 5.8 N/A N/A
230/1/60 15 6.2 15 5.8 N/A N/A
K0500
115/1/60 20 12.7 20 12.0 N/A N/A
230/1/50 15 6.3 15 5.9 N/A N/A
K0600
208-230/1/60 20 9.2 20 8.8 N/A N/A
230/1/50 20 8.6 20 8.2 N/A N/A
K1000
208-230/1/60 20 13.9 20 13.2 20 12.8
230/1/50 20 13.8 20 13.1 20 14.1
K1350
208-230/1/60 20 – 20 – 20 –
230/1/50 20 – 20 – 20 –