130 Part Number STH063 9/17
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
Freeze Time Harvest
Time
9.8-11.2 10.2-14.8 10.6-12.1
1.0-2.5
10.0-11.4 10.6-12.1 11.5-13.1
10.7-12.2 11.9-13.5 13.4-15.2
12.3-13.9 12.6-14.3 14.5-16.4
12.6-14.3 13.6-15.4 15.2-17.2
Times in minutes
24 Hour Ice Production
Air Temp. Entering
1650 1565 1460
1560 1480 1370
1470 1420 1280
1380 1345 1190
1345 1260 1140
Based on average ice slab weight of 13.20 - 14.80 lb (5.99 – 6.71 kg)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Entering
Condenser
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
270-285 60-38 170-190 120-135
300-320 60-38 180-210 130-140
300-340 60-39 180-210 130-140
310-380 70-40 180-210 130-140
380-460 80-41 200-210 135-150
400-480 85-42 210-220 140-155
Suction pressure drops gradually throughout the freeze cycle