EasyManua.ls Logo

Koolaire KDT0400A - KT0700 W Self-Contained Water-Cooled

Default Icon
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
124 Part Number STH063 9/17

NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Around Ice
Machine

Freeze Time Harvest
Time

  
 7.5-8.9 8.2-9.7 9.6-11.3
1.0-2.5
 7.8-9.2 8.5-10.0 9.8-11.5
 7.9-9.4 9.3-10.9 10.0-11.8
 8.4-9.9 9.8-11.5 10.3-12.0
 8.7-10.2 10.4-12.2 11.0-12.9
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice


  
 660 610 535
 640 595 525
 630 550 515
 600 525 505
 585 500 475
Based on average ice slab weight of 4.125 – 4.75 lb (1.87 – 2.15 kg)
Water regulating valve set to maintain 300 PSI discharge pressure
Condenser Water usage per 100 lbs ice = 140 gal (45 kg = 530 L)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Around Ice
Machine

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 295-305 55-31 145-180 115-140
 295-305 55-32 155-190 120-140
 295-305 60-32 155-190 120-140
 295-305 65-32 155-190 120-150
 300-325 65-32 160-190 125-150
 300-325 65-32 165-190 130-150
Suction pressure drops gradually throughout the freeze cycle

Table of Contents

Related product manuals