5.
TEST
program
Explanation
■OUTLINE
OF
DSS-1
INTERNAL
INSPECTION
MODE
The
inspection
program
given
below
is
stored
in
the
DSS-1
system
ROM.
When
the
power
switch
is
switched
from
OFF
to
ON
while
pressing
both
the
DATA
ENTRY
A
section
UP
and
DOWN
keys
(A
T)
simultaneously,
the
TEST
MODE
is
activated.
In
this
mode,
the
system
runs
in
the
following
sequence,
and
inspection
is
carried
out.
Software:
version
indication
and
date
indication
FDD
function
test
W^RAM
test
Panel
switch
confirmation
It
is
convenient
for
one
FD
to
be
set
aside
to
be
used
ex
clusively
for
FDD
tests.
(Caution)
For
FDD
tests,
use
one
that
has
already
been
formatted.
Also,
when
an
FDD
test
is
run,
all
of
the
data
are
erased.
Note
2,
MIDI
MIDI
is
"90",
"3C"
and
"40"
note-on
data
signals.
Every
time
the
voice
changes
from
1
to
8,
conversion
to
the
following
data
is
performed
(the
lower
4
digits
of
the
status
change).
Notel
After
entering
"SYSTEM
MODE",
everything
is
in
normal
status
except
for
the
following
conditions:
MASTER
TUNE,
PITCH
BENDER,
AUTO
BEND,
and
PITCH
MODULATION
are
ineffective.
VOICE
NO.
data
are
output
to
MIDI-OUT.
VOICE
NO.
is
indicated
on
LCD
in
PLAY
MODE.
35