One-Touch Recording
1. Choose any Program or a Combi Ä Tap the TIMBRE/TRACK key at least 3x to enter a desired tempo.
2. Hold down ENTER and press REC/WRITE
Ä Press F8 to answer “OK” to “Setup to Record: Are you sure?”
Ä Triton Le jumps to Record mode, with the REC/WRITE key already armed.
3. Press START/STOP to begin recording
Ä Press START/STOP again to stop recording. What could be
easier?!
Alternate song method for copying Combis with Arpeggio Patterns
1. Choose any Combi with the ARP ON/OFF switch on (lit).
2. Press the SEQ key and create a new song Ä Press F8, Utility and CURSOR to “Copy from Combi” Ä
Confirm OK with F8
Ä CURSOR to and check both boxes “with Effects” and ”Auto Adjust Arp for Multi
REC”
Ä Confirm OK by pressing F8.
3. Press START/STOP to begin recording Ä Press START/STOP again to stop recording.
Using the Swing Quantize function
1. Press MENU Ä Press F5, then CURSOR ▼to T Edit Ä Press F8 to Open Ä Select a Track to edit; select the
first four measures as a region to edit (from M:001 to End of M:004).
2. Press F8 Utility and CURSOR to Quantize
Ä Press F8 to confirm OK Ä Set Resolution to the 16
th
note icon,
and DIAL (or type in, pressing Enter after) a swing percentage and press F8, OK.
Sampling with the EXB-SMPL Option
The user-installable EXB-SMPL sampling option provides the user with everything needed for serious sampling: a
pair of audio inputs with Level control and Mic/Line level switching, a SCSI connector, and 16 MB of Sampling
RAM.
The Triton LE samples at 48 kHz, 16-bit, in mono or stereo. With the provided 16 MB, the Triton LE is capable of
recording samples of 174 seconds @ mono, or 87 seconds @ stereo. Fully expanded with SIMM modules to 64 MB,
it allows about 11 ½ mono minutes or 5.8 stereo minutes of sampling! The correct SIMMS are 72-pin, non-parity,
EDO or Fast Page (FPM) DRAM SIMM, 60 ns (nanoseconds) or faster, 11 Bit Addressing.
Recording “one-shot” vocal samples
1. Connect a microphone to the AUDIO INPUT 1 jack on the rear panel, set the MIC/LINE switch to MIC, and
set the LEVEL control to the 12 o’clock position.
2. Press the SAMPLING key
Ä Press F1 (“Sample” tab) and make sure that “MS” (Multisample) is set to “000:
new MS____000”
Ä CURSOR to, and set both the “Orig K” and “Top K” (original and top key) fields to a
value of “C2”. The easiest way to set this is by holding down the ENTER key and pressing the C2 key on
the keyboard.
3. Press F3 (“In/Pref”)
Ä CURSOR ► to “Input 1 Pan”, and set this value to “C064” with the DIAL or
numeric keypad (Enter 6 > 4, followed by pressing the ENTER key).
4. CURSOR ► to “Input 1 BUS”
Ä Set this value to “L/R” Ä CURSOR to the “Create” edit cell and set the
“Range” value to “001”.
5. Press F2 (“Rec”), and in “Sample Setup”, CURSOR ► to “Mode” and set to “L-Mono”.