[>TEMP LIMIT] maximum temperature limit (min setting - max setting)
Notice: a new maximum temperature value will be saved in memory for other
temperature settings as well,
If you try to set the temperature above the adjusted maximum value the display
will show for about 1 second.
[>HE TEST] for authorized service only,
[>POWER SET] congured power value,
- push knob to check a software version (PW...,MSP...),
- restore to factory settings [FACTORY SET] or to restart controllers [RESET],
- push and keep knob (for about 5sec., until the display show [--]) to up grate [FAC-
TORY SET] and [RESET] function,
[>EXIT] save a new parameters and menu exit.
Notice: parameters view mode will automatically exit (without saving changes) after
5 minutes since the last adjustment.
PPVE Operation
A
B
The heater switches on automatically straight
after reaching the ow rate over 2,5 l/min. The
temperature control system adjusts the power rate
according to the water ow rate, required tem-
perature and the water temperature in the mains.
The LCD red colour backlight and icon sig-
nalises the heating operation. If the unit reach
the maximum power value which is too low for a
given
operating conditions the LCD display will
show . The LED display backlight also turns.
The heater switches on automatically straight
GB
after reaching the ow rate over 2,5 l/min. The temperature control system adjusts
the power rate according to the water ow rate, required temperature and the water
temperature in the mains.
The LCD red colour backlight and icon signalises the heating operation. If the unit
reach the maximum power value which is too low for a given
operating conditions the
LCD display will show . The LED display backlight also turns on while pushing
or turning the setting knob. The backlight will automatically turn off when the heating
operation is turned off, or if more than 30 seconds have passed since the last adjust-
ment. If you block the unit (NA entry) by master appliance the display will show .
If the fault occurs the display will show error message:
ERR
Tin
- inlet sensor failure,
ERR
Tout
- outlet sensor failure,
ERR
Tmax
- temperature has exceeded the maximum value,