Model | PIKO 8.3 |
---|---|
Max. apparent AC power | 8.3 kVA |
AC nominal power | 8.3 kW |
Number of MPP trackers | 2 |
Max. input voltage | 1000 V |
Operating temperature range | -25 °C to +60 °C |
Warranty | 5 years |
Nominal AC frequency | 50 Hz |
Protection Class | I |
Identifies intended readers for specific manual chapters.
Defines hazard levels (DANGER, WARNING, CAUTION) and their consequences.
States manufacturer is not liable for damage from use outside intended purpose.
Labels must not be changed; installers must follow regulations and manual.
Recommends overvoltage protection type 2 for lightning protection.
Warns pacemaker users to consult a doctor before entering site.
Covers unit opening, cable handling, hot components, and fire risks.
Describes the basic function of PIKO inverters and their technology.
Explains connection of solar modules via strings and plug-in connectors.
Explains using generated electricity directly and reducing grid load.
Discusses temporary output limitation for grid stability in Germany.
Explains control of reactive power feed-in as per regulations in Germany.
Provides guidance on handling and storing the inverter before installation.
Lists the items included in the inverter packaging.
Details criteria for choosing a suitable location for the inverter.
Provides instructions for mounting the inverter on the wall.
Covers opening housing, connecting AC and DC sides of the inverter.
Instructions for setting the country for correct grid monitoring functions.
Connecting components, web server configuration, data transfer options.
Installing sensors, switch output, S0 input, RS485, and ripple control receivers.
Steps for closing the inverter housing after installation.
Procedure for starting up the inverter after installation.
Guide to configuring communication and accessories via web server.
Adjusting various inverter settings via the web server interface.
Procedures for safely switching off and decommissioning the inverter.
Instructions for routine checks and maintenance of the inverter.
Procedures for disassembling and properly disposing of the inverter.
Overview of display, LEDs, and status messages for monitoring operation.
Navigating menus to view data and change settings on the inverter.
Information on inverter faults, causes, and initial checks.
Steps to access the inverter's web server for monitoring and configuration.
Methods to obtain and analyze logged performance data from the inverter.
How to deactivate automatic data export to a solar portal.
Detailed technical specifications for different PIKO inverter models.
Illustrates the internal functional components of the PIKO inverter.
Explains type plate details and provides warranty/service contact info.