VM4HDT, VM3HDT, VM2HDT Protocol 3000
20
Command
Description
RESET
Reset device (system mandatory)
SN
Get device serial number (system mandatory)
DISPLAY?
Get output HPD status
SIGNAL?
Get input signal lock status (system)
#
Functions
Permission
Transparency
Set:
#
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Protocol handshaking
#CR
Get:
-
-
Response
~nn@SPOKCR LF
Notes
Validates the Protocol 3000 connection and gets the machine number.
Step-in master products use this command to identify the availability of a device.
K-Config Example
“#”,0x0D
BUILD-DATE
Function
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
Get device build date
#BUILD-DATECR
Get:
-
-
Response
~nn@BUILD-DATESPdateSPtimeCR LF
Parameters
date - Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time - Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
K-Config Example
“#BUILD-DATE?”,0x0D
FACTORY
Function
Permission
Transparency
Set:
FACTORY
End User
-
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory defaults configuration
#FACTORYCR
Get:
-
-
Response
~nn@FACTORYSPOKCR LF
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
K-Config Example
“#FACTORY”,0x0D