6 39
220 V
Electrical connection
The machine is supplied with an electrical power cord with plug.
The mains plug must be fitted to a standard grounded socket with a 30mA residual current
operated device.
The socket must be protected with a 16A delay action fuse on the mains side.
KRÄNZLE 2170 TST = 220 Volt / 60 Hz (phase-sequence
not significant
)
When using an extension cable, this must have an earthed lead which is properly
connected to the socket. The conductors in the extension cable must have a
minimum cross section of 2.5 mm². Plug connections must be of a spray-proof
design, and may not be located on a wet floor.
(with extension cables of more than 10 m - 4.0 mm
2
)
CAUTION !
The use of extension cables which are too long may lead to malfunctions and
start p difficulty.
When using a cable drum, always keep the cable wound as far as possible.