Preparation for use
5. The machine must be connected to the water
line with cold water or up to 60° C warm water
(see page 2).
The hose cross section must be at least
3/4" = 16 mm (free passage). Filter 1 must
always be clean.
Please make sure that the lter is clean be-
fore using your high pressure cleaner.
CAUTION !
When running your high pressure cleaner with hot water of 60° C rai-
sed temperatures occur.
Do not touch the pump without safety gloves!
13
Undercarriage
Undercarriage
1
External suction
If water is to be sucked
from an external contai-
ner for the high pressure
cleaner, the connection
hose between the high
pressure pump and the
water tank must be scre-
wed off and the suction
hose must be connected
via a double nipple 3/4“ (Order no.: 46.004) to the con-
nection hose.
Make sure that the water is clean. Use the Kränzle suction hose with suction lter.
(Order no. 15.038 3)
Maximum suction height 2.5 m, maximum water temperature for direct suc-
tion: 60°C
(see technical data on page 2)