Description
400 V / 50 Hz
Electrical connection
The machine is supplied with an electrical power cord with plug.
The mains plug must be tted to a standard grounded socket with a 30mA re-
sidual current operated device. The socket must be protected with a 16A delay
action fuse on the mains side.
KRÄNZLE quadro = 400 Volt / 50 Hz (phase-sequence not signicant)
When using an extension cable, this must have a grounded lead which is properly
connected to the socket. The conductors in the extension cable must have a mini-
mum cross section of 1.5 mm². Plug connections must be of a spray-proof design
and may not be located on a wet oor.
CAUTION !
The use of extension cables which are too long may lead to malfunctions and
start up difculty.
When using a cable drum, always keep the cable wound as far as possible.
8