Care and Maintenance
Changing the oil
The oil of your high pressure pump should be changed after approx 40 hours of
operation or if it has a grey or whitish appearance..
To do this, take the oil drainage hose (1) from the inside of the machine and open
the oil filler cap (2) on the top side of the oil reservoir. Open the bung (3) at the end
of the hose. Drain off teh oil and dispose of it responsibly. Close the end of the
hose.
Refill with oil until the sight glass is full.
Type of oil: Formula RS (Castrol) or semi-synthetic motor oil
Quantity: 1,0 l
3
2
1
Fuel System
Your fuel may contain particles of dirt, or impurities may get into the tank during
refuelling. Check the tank for impurities on a regular basis. Clean the tank when
necessary
Empty the fuel tank using the drainage screw at the bottom of the tank. Clean the
tank and fuel lines.
Replace the drainage screw.
Detergent and dirty fuel must be disposed of responsibly.