DESCRIPTION OF THE LABEL M ARKINGS
The CYCLOMIX
TM
MICRO machine is fitted with 2 label markings : a label marking on the control bay and the
other one on the fluid module.
Marking label on the control bay
(bay located outside
the spray booth)
Marking label on the fluid module
(fluid module located outside the spray
booth Æ marking in accordance with the
ATEX directive)
MarkinginaccordancewiththeATEXdirective
KREMLIN REXSON
STAINS FRANCE
Name and address of the manufacturer
CE II 3 G
II :groupII 3 :class3
Surface equipment meant to area where explosive atmospheres due to gas,
vapours, mists are not liable to appear from time to time in usual operating or
if they appear nevertheless, it is for a short duration.
G :gas
P air : 6 bar / 87 psi Maximum air pressure
Pprod:175bar/2536psi
Maximum fluid pressure
Ref
CYCLOMIX
TM
MICRO machine part number
Caution!
The CYCLOMIX
TM
MICRO mixing machine must be installed outside the explosive area.
It must be installed in a safe area (non explosive area according to the ATEX directive).
The display unit must be moved 1 m / 3.3 ft away from the fluid module and not be
installed above that one.
The control bay must be connected to a mains supply fitted with a ground.
The ground of t he fluid module must
be grounded.