Flow rates natural gas [m
3
/h]
mbar
inch WC
Pressure drop ∆p
207 9 30 40 50 60 80 100
8 10
0.2 0.3 0.4 0.6 0.8 1 2
200 700300 400 500
3 4 5 6 8 10 20
SCFH
20
30
40
4
5
6
8
10
10
20
30
40
50
60
80
100
ø
GIK: bypass plug – standard no hole
GIK..B: bypass plug – standard * GIK 15–25..B: 0.06 inch (1,5 mm)
** GIK 40–50..B: 0.197 inch (5 mm)
Bypass screw GIK..B
inch (mm) Ø
0.06 (1.5)*
0.079 (2
)
0.118 (3
)
0.157 (4
)
0.197 (5)*
*
0.236 (6
)
0.267 (7
)
0.315 (8
)
0.354 (9)
GIK 15–25..B
GIK 40–50..B
To adjust the low fire position at GIK..B (with
internal Bypass)
• The air control line (air control pressure) must be
less than 0.8" WC (2 mbar) at low fire position
• The bypass screw and the housings have been
marked since Nov. 2000. Only marked screws may
be used with marked housings
• The bypass orifices determines the low fire rate.
Standard:
GIK 15 to 25 (½” to 1”) = 0.059 “ (1.5 mm)
GIK 40 to 50 (1½” to 2”) = 0.20 “ (5 mm)
GIK 65 to 100 (2½” to 4”) = use external Bypass
• Enlarge the orifice if necessary (max.)
GIK 15 to 25 (½” to 1”) = 0.16 “ (4 mm)
GIK 40 to 50 (1½” to 2”) = 0.35 “ (9 mm)
Operation
Order-No. Bypass Screws
For GIK 15 to 25 (½" to 1")
Bypass screw ∅ 0.059" (1.5 mm)
03089217
Bypass screw without orifice
03089215
Bypass variable 74919806
For GIK 40 to 50 (1½" to 2")
Bypass screw ∅ 0.2" (5 mm)
03089218
Bypass screw without orifice
03089216
Bypass variable
74919821