12
T-Product · GIK, GIK..B · 2004 November
1 2 3
4 5
max. 300 mbar
GIK 15–25..B,
GIKH 25..B
GIK 40–50..B
The bypass screws
and the housing
have had markings
since November
2000. Only marked
screws may be used
with marked
housings.
Flow rates natural gas [m
3
/h]
mbar
inch WC
Pressure drop p
207 9 30 40 50 60 80 100
8 10
0.2 0.3 0.4 0.6 0.8 1 2
200 700300 400 500
3 4 5 6 8 10 20
SCFH
20
30
40
4
5
6
8
10
10
20
30
40
50
60
80
100
ø
GIK: bypass plug standard no hole
GIK..B: bypass plug standard * GIK 15–25..B: 0.06 inch (1,5 mm)
** GIK 40–50..B: 0.197 inch (5 mm)
Bypass screw GIK..B
inch (mm) Ø
0.06 (1.5)*
0.079 (2
)
0.118 (3
)
0.157 (4
)
0.197 (5)*
*
0.236 (6
)
0.267 (7
)
0.315 (8
)
0.354 (9)
GIK 1525..B
GIK 4050..B
To adjust the low re position at GIK..B (with
internal Bypass)
The air control line (air control pressure) must be
less than 0.8" WC (2 mbar) at low fire position
The bypass screw and the housings have been
marked since Nov. 2000. Only marked screws may
be used with marked housings
The bypass orices determines the low fire rate.
Standard:
GIK 15 to 25 (½ to 1) = 0.059 “ (1.5 mm)
GIK 40 to 50 (1½ to 2) = 0.20 “ (5 mm)
GIK 65 to 100 (2½ to 4) = use external Bypass
Enlarge the orice if necessary (max.)
GIK 15 to 25 (½ to 1) = 0.16 “ (4 mm)
GIK 40 to 50 (1½ to 2) = 0.35 “ (9 mm)
Operation
Order-No. Bypass Screws
For GIK 15 to 25 " to 1")
Bypass screw 0.059" (1.5 mm)
03089217
Bypass screw without orice
03089215
Bypass variable 74919806
For GIK 40 to 50 (1½" to 2")
Bypass screw 0.2" (5 mm)
03089218
Bypass screw without orice
03089216
Bypass variable
74919821