Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Ferric sulphate (II) 5 80 Boiler feed water to VdTÜV1466 140
Iron phosphating solution (alkaline phosphating) approx
. 5
70
Cooling water
4)
(without anti-freeze)
60
Acetic acid 10 60 Closed circuit cooling water 100
Acetic acid 5 60 Open circuit cooling water 100
E-coating (water), anaphoresis 35 Cooling water pH value > 7.5 (with anti-
freeze)
6)
110
E-coating (water), cataphoresis 35 Paint-laden water containing residues of wood
paints
30
Ethanol 60 Paint-laden water containing residues of
plastics paints
30
Ethylene glycol 100 Paint-laden water containing residues of metal
paints
30
Ethylene glycol base anti-freeze, inhibited, closed
system
50 110
Slightly contaminated water
4)
60
Tannic acid 20 80 Tap water 60
Glycerine 40 80
Clean water
7)
60
Potassium hydroxide 5 40
Raw water
4)
60
Potassium nitrate, acid-free 5 30
Swimming pool water (fresh water)
4)
60
Potassium sulphate, acid-free 3 20 Lake water (fresh water) 60
Kerosene (jet fuel) 80 Barrier water 70
Condensate
5)
120 Fresh water 60
Condensate, not conditioned 120 Dam water 60
Conventional paint on solvent basis 10-40 Partly desalinated water 120
Copper sulphate 5 80
Drinking water
4)
60
Magnesium sulphate 10 80 Permeate (osmosis) 140
Maleic acid 10 60 Ultrafiltrate = permeate, pure filtrate, solids
content <1 %
30
Milk 60 Deionised water, free of solids 60
Lactic acid 5 60 Fully desalinated water 120
Lactic acid 40 60 Hot water (brewery) 60
Sodium carbonate 6 60 Water treated to VdTÜV1466 140
Sodium hydroxide 5 40
Water with anti-freeze, pH value > 7.5
4) 6)
110
Sodium nitrate, acid-free 10 60 Water, waste water, slightly contaminated
water, surface water
60
Sodium sulphate, acid-free 5 60 Water, fire-fighting water 60
Sodium hydroxide 15-20 20 Water, surface water 60
Oils/emulsions Water, rainwater, with strainer 60
Peanut oil 90 Water, raw water 60
Corn oil 100 Water, drinking water 60
Linseed oil 60 Tartaric acid 8 40
Rapeseed oil 100 Citric acid 25 30
Soybean oil 100 Lye for bottle rinsing 90
Spare parts
List of spare parts
Description Ident. No.
Pressure sensor
-1..3 bar 0.6 m cable (red)
01146960
Pressure sensor
-1.0.10 bar 0.6 m cable (blue)
01146961
Description Ident. No.
Pressure sensor
-1.0.16 bar 0.6 m cable (light grey)
01146962
Pressure sensor
-1..25 bar 0.6 m cable (green)
01146963
Pressure sensor
-1..40 bar 0.6 m cable (black)
01146965
6)
Anti-freeze on ethylene glycol basis with inhibitors. Content: >20 % to 50 % (e.g. Antifrogen N)
7)
No ultra-pure water! Conductivity at 25 °C: < 800 µS/cm, neutral with regard to chemical corrosion
Monitoring
Intelligent Pressure Sensor