Dimensions of the display unit
Scope of supply
▪ Display unit fitted
▪ Sensors fitted with adapter
Fluids handled
Overview of fluids handled
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Alum, acid-free 3 80 Diesel oil – 80
Alkaline solution, bottle rinsing, max. 2% sodium
hydroxide
– 40 Diesel oil, fuel oil EL – 60
Alcohol – – Lubricating oil, turbine oil, does not apply to
SF-D oils (hardly flammable)
– 80
Aluminium sulphate, acid-free 5 60 Heating oil – 80
Ammonium bicarbonate 10 40 Water-oil emulsion (95%, 5%), free of solids – 80
Ammonium sulphate 20 60 Phosphate sludge …10 60
Anolyte (dialyte) with acetic acid or formic acid,
free of solids
– 30 Phosphoric acid 5 20
Accelerator (as preparation) – – Propanol – 80
Drilling/grinding emulsion – 60 Cleaning agents – –
Spirits (40% ethanol) – 60 Juice (fruit and sugar juice) – 60
Service water – 60 Nitric acid 15-20 80
Brewery applications – – Silicate-free, alkaline degreasing or cleaning
solution containing solid particles
0.3-5 80
Beer mash – 100 Fuel – –
Beer wort – 100 Trisodium phosphate 4 80
Brewing water – 60 Water – –
Ice water (brewery) – 60 Deionised water (fully desalinated) – 140
Vapour condensate (brewery) – 140 Dealkalised water – 120
Butanol – 60 Decarbonised water – 120
Calcium acetate, acid-free 10 60
Fire-fighting water
4)
– 60
Calcium nitrate, acid-free 10 60 River water – 60
Diethylene glycol – 100
Heating water
5)
– 140
4)
General criteria for results of water analysis: pH value ≥ 7; chloride content (Cl) ≤ 250 mg/kg. Chlorine (Cl 2) ≤ 0.6 mg/kg
5)
Treatment to VdTÜV 1466; additional requirement: O2≤ 0.02 mg/l
Monitoring
Intelligent Pressure Sensor