EasyManua.ls Logo

Kubota D1102-B - Motor Unit Removal; Reduction Type Starter Brush Holder Removal; Reduction Type Starter Armature Removal

Kubota D1102-B
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KiSC issued 09, 2007 A
a
w
,
.
Checking Negative Diodes
1 ) Check the conduction across each M5 screw and coil
connecting terminal (outside).
2) If any diode is faulty, replace its whole negative diode
assembly.
(Important)
When reassembling, remember that diodes are very sensi-
tive to heat.
84
C))
Checking Conduction across N Terminal and
Coil Connecting Terminal
1)
Check the conduction across N terminal and coil connect·
ing terminals (inside) .
2)
If not conducting, replace.
(
1
)
N terminal
Reference value
If the ohmmeter indicates a specified value when the positive
probe is applied to the coil connecting terminal and the nega-
tive probe to the M5 screw, and if it indicates infinity when the
probes are reversed, the negative diodes are normal.

Table of Contents