S.5
ELECTRICAL
SYSTEM
68
mm
STROKE SERIES
WSM,
01 160
Glow
plug
resistance
[2]
STARTER
::::ry
Approx.
0.9
Q
Motor Test
0302P151
0302~158 0302P159
[3]
GLOW
PLUG
L_o__I
DO1
1F177
1.
Disconnect the connecting lead from the
"C"
terminal
of
the starter and connect a jumper lead
from the connecting lead to the positive battery
terminal.
2.
Connect a jumper lead momentarily between the
starter body and the negative battery terminal.
3.
If
the motor does not run, check
the
motor.
Magnet
Switch
a
NOTE
Each
test
should be carried out for a start time
(3
to
5
seconds), and
at
half
of
the rated voltage
(6W.
1)
Checking Pull-in
Coil
1.
Connect jumper lead from the battery's negative
terminal post to the
C
terminal.
2.
The plunger should be attracted strongly when a
jumper lead
is
connected from the battery positive
terminal
to
the
S
terminal.
2)
Checking Holding
Coil
1.
Connect jumper leads from the battery's negative
terminal post
to
the body and the battery's
positive terminal post
to
the
S
terminal.
2.
Push the plunger
in
by hand and release
it.
Then,
the plunger should remain being attracted.
5-131