5SPECIFICATIONS
ENGLISH
B3 Phase Type
GENERATOR
Model Unit
J310 J313
-STD -AUS -STD
Design
Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
Frequency Hz 50 60
Rated Output (COP)
kVA 10 10 6 12.5
kW 8 8 6 10
Rated Voltage V 380 415 240 220
Phase & Wire φ-w 3-4
Power Factor % 80 80 100 80
No. of Poles - 2
Insulation - Rotary coil: Class F, Stator coil: Class B
Voltage Regulation % 8 (No load to full load)
Type of Coupling Direct coupled
DIESEL ENGINE
Model D722-B-SEC
Design Vertical, water-cooled, 4-cycle diesel engine
No. of cylinders 3
Bore x stroke mm φ67 x 68
Displacement L 0.719
Engine speed rpm 3000 3600
Lubricating Oil API service class CD or higher
Oil capacity L 3.4
Coolant capacity L 3.0
SET
Fuel Diesel fuel No. 2 (ASTM D975)
Fuel consumption (at full load) L 3.2 4.2
Fuel tank capacity L 37
Continuous Operating Hours hrs 11.5 8.5
Battery (V x Ah/5Hr) 55B24R (12V x 36Ah)
Starting System Electric
L x W x H (with wheel) mm 995 x 593 x 860 (1037)
Approx Net Wt. kg 255
Output
Terminal - -
Receptacle - - -
Option Caster -
Sound Level (full load at 7m) dB(A) 75.0 76.5
Emergency Stop System - In case of abnormal: Oil pressure, water temperature
AMPS
AMPS A 15.2 13.9 8.3 x 3 32.8