Why is there insufficient tailgate power in my KUHN Farm Equipment?
- QqramosAug 20, 2025
Insufficient tailgate power during loading with your KUHN Farm Equipment may stem from a hydraulic problem. Verify that the hydraulic connection between the tractor and the machine is correctly set up for both pressure and return. It is also recommended to have your dealer check the hydraulic pressure (180 bars) and the pump flow (30 l/min.). The return pressure should be at least 8 bar when the tractor engine is at its nominal speed.