Mounting the hood body
Before attaching the hood body, tighten the two
screws Vr located on the hood body mounting
points.
Hook the hood body onto the screws 12a
Fully tighten support screws 12a
Adjust screws Vr to level the hood body.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe
ø 150 or 120 mm, the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the hood body
outlet.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
Lean the air outlet junction 7.4 against the wall and place
it under the upper fixing bracket 7.2.1 centring it to the
vertical reference line.
Mark the centre of the fixing slots.
Drill ø 8 the marked points.
Put the dowels 11 into the holes.
Fix the flange 10 to the lower opening of the junction
piece 7.4.
Fix the junction piece to the wall using the 2 screws 12a
(4,2x44,4) (supplied).
Cut the gasket 13 into two pieces of same size and place
them to the round shaped part of the junction piece.
Connect the hood air outlet to the flange in the lower part
of the junction using a rigid or flexible ø 150 tube (by
installer's choice).