SECTION 4
DIAGSO_4.DOC
12/22/92
When
the
diagnostic
test
menu
is
displayed,
press
the
A
soft
button
(the
farthest
to
the
left)
at
any
time
to
begin
the
Burn-in
test
sequence.
When
the
Burn-in
test
is
selected,
the
display
changes
to
show
the
list
of
tests
included
in
the
Burn-in
sequence.
As
each
test
is
completed,
the
display
is
updated
to
show
the
result.
See
Figure
4.4.
The
Burn-in
test
is
adequate
for
testing
the
unit's
major
components;
if
all
the
Burn-in
tests
pass,
the
unit
should
be
in
full
working
order.
NOTE: An
SCSI
device
must
be
connected
to
the
unit's
SCSI
port,
otherwise
the
SCSI
test
will
fail.
This
does
not
necessarily
indicate
a
malfunction
of
the
SCSI
link.
Exit-Break
Total-0000
Fail-0000
Figure
4.4.
Burn-in
Test
Menu
The
Burn-in
test
can
be
aborted
at
any
time
by
pressing
the
EXIT
button,
then
pressing
any
button
on
the
front
panel
to
return
to
the
diagnostic
test
menu
(the
display
says
"Press
any
key,"
meaning
a
front
panel
button,
not
one
of
the
black-and-white
keys).
It
may
be
necessary
to
press
the
EXIT
button
more
than
once,
because
the
K2000
can
only
recognize
switch
closures
between
tests.
Press
any
front
panel
button
to
interrupt
the
Burn-in
test
temporarily.
The
test
will
resume
when
the
button
is
released.
Press
anyone
of
the
keys,
the
test
will
be
interrupted
and
hold
temporarily;
it
will
resume
when
any
front
panel
button
is
pressed.
4.12.3
Selecting
a
Specific
Test
To
run
an
individual
test,
use
the
Alpha
Wheel
to
select
the
desired
test
from
the
diagnostic
test
menu.
The
selected
test
is
highlighted
in
reverse.
Press
the
ENTER
button
to
run
the
selected
test
one
time.
When
the
test
is
completed,
the
display
will
show
the
result
of
the
test.
Normally
each
test
need
only
be
run
once
in
the
attempt
to
identify
failures.
Running
a
given
test
continuously
is
recommended
to
monitor
the
K2000's
output
signal
with
an
oscilloscope,
since
many
tests
are
completed
too
quickly
to
be
monitored
in
a
single
pass.
4.12.4
Continuous
Testing
A
selected
test
can
be
run
indefinitely
by
pressing
the
B
soft
button
(second
from
the
left).
This
will
cause
the
selected
test
to
run
until
it
is
interrupted
with
the
EXIT
button.
Remember,
it
may
be
necessary
to
press
the
EXIT
button
more
than
once.
Press
any
front
panel
button
to
interrupt
a
continuous
test
temporarily.
The
test
will
resume
when
the
button
is
released.
Press
one
of
the
keys,
the
test
13