KPO PORTABLE AIR CONDITIONERS KWIKOOL
13
When set in AUTO FAN (AF), the supply air in COOL mode will only operate when the compressor
is on. The letters AF show on the display when using this feature
When set in MANUAL FAN, the supply air fan in the COOL mode is always on. AF will not display
in MANUAL FAN. This feature is only available in COOL mode
The supply air is always on in HEAT or FAN mode and the supply air may operate in the OFF mode
if set in HEAT and turned off before the cycle was completed
C OPERATING MODES
FAN MODE
1. Set mode to fan.
2. The fan icon displays solid and the supply air fan starts with no cooling or heating operation.
3. A short press on the power button stops the fan operation.
COOL MODE
1. Set the mode to cool, a 2.5-minute time delay starts for the compressor to prevent short cycling,
signified by F or C blinking on and off on the display
2. Adjust the set point below the room temperature displayed on the control to the desired temperature
3. Select FAN. This requires a short press on the icon to display AF (AUTO FAN) for supply fan oper-
ation when the compressor starts.
4. If already in ON mode, a short press on the FAN icon begins continuous supply fan operation (AF
will not display when using this feature).
5. Press ON. If the time delay is finished, the icon for COOL starts to blink, the compressor starts, and
cooling will begin. After the system has built up enough pressure, the hot air exhaust fan will start to
ramp up. It is normal for this fan to delay in starting and normal for it to slow down and speed up
during the operating process.
NOTE
The hot air exhaust fan (condenser discharge) is not operational in
Heat or Fan mode. It only operates in Cool mode.
HEAT MODE (Optional)
Set the mode to HEAT. Adjust the set point above the room temperature displayed on the control to the
desired temperature. Press ON and heating will begin.
Fire rated or high temperature duct is NOT required to use with the KPO series in heat mode. The heat
rating for KPO systems is as follows: KPO25 is 48 KVA, KPO12 is 24 KVA, and KPO5 is 12 KVA.
NOTE
Operators do not have control of the supply fan in this mode. The
supply air fan is always on when ON is selected.