Work Shop use only-Controller work shee
79
Work Shop use only-Rear position light
CONTROLLER PARAMETERS
DESIRED SETTINGS RANGE UNITS
DESCRIPTION
FAST SLOW
FORWARD ACCELERATION
20 30
0.1 TO 10S
FAST / SLOW
FORWARD DECELERATION
810
0.1 TO 10S
FAST / SLOW
REVERSE ACCELERATION
30 40
0.1 TO 10S
FAST / SLOW
REVERSE DECELERATION
15 15
0.1 TO 10S
FAST / SLOW
FORWARD SPEED
95 50
0 TO 100%
FAST / SLOW
REVERSE SPEED
50 30
0 TO 100%
FAST / SLOW
THROTTLE INVERT
NO
YES/NO
SLEEP TIMER
20
0 TO 20
MINUTES
Read system log
PARAMETER NO.:36010-LHD7-900
ECU
:
36000-LDH7-900
EQ20CA(UK)
P&G Sdrive 24 Volt 110Amp
CONTROLLER WORKSHEET
Switch the Scooter off.
Removing the floor panel cover bolts.
Removing. floor panel cover .
Remove the rear position light connector and bolts.
Remove the rear position light comb.
Installation is in the reverse order of removal.
Correct Wrong