EasyManua.ls Logo

KYORITSU 3132A User Manual

KYORITSU 3132A
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
92-1493A 03-08
KYORITSU ELECTRICAL
INSTRUMENTS
WORKS, LTD.
No.5-20,Nakane 2-chome, Meguro-ku, Tokyo
152-0031 Japan
Phone :(03) 3723-0131 Fax : (03) 3723-0152
URL : http://www.kew-ltd.co.jp
E-mail : info@kew-ltd.co.jp
Factories : Uwajima & Ehime
Kyoritsureservestherightstochangespecificationsordesigns
describedinthismanualwithoutnoticeandwithoutobligations.
DISTRIBUTOR
INSTRUCTION MANUAL
ANALOGUE INSULATION-CONTINUITY TESTER
MODEL 3132A
KYORITSU ELECTRICAL INSTRUMENTS
WORKS, LTD.
3132A-E/03-0803.8.610:33AMページ表4
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Question and Answer IconNeed help?

Do you have a question about the KYORITSU 3132A and is the answer not in the manual?

KYORITSU 3132A Specifications

General IconGeneral
AC Voltage Ranges600 V
TypeInsulation Tester
AC Voltage Range600 V
AC Current RangesNot applicable
Resistance Ranges0.1MΩ to 2000MΩ
Test Current1mA at 250V, 1mA at 500V, 1mA at 1000V

Summary

Safety Precautions

Features

Specifications

Instrument Layout

Preparation for Testing

Mechanical Zero Adjustment

Align the pointer with the middle of the scale mark for correct zero adjustment.

Battery Voltage Check

Verify battery status by checking the pointer deflection against the BATT.GOOD mark.

Test Probe Connection

Connect the black earth clip to the EARTH terminal and the red line probe to the LINE terminal.

Test Probe Check

Short probes and check pointer movement to verify probe or fuse integrity.

Operation

AC Voltage Warning Function

Detects AC voltage presence automatically when the test button is not depressed.

Insulation Resistance Measurement

Measures insulation resistance by applying high voltage and measuring current.

Continuity Testing (Resistance Tests)

Tests continuity by applying current and measuring voltage across the resistance.

Battery & Fuse Replacement

Battery Replacement

Replace all six batteries with new ones of the specified type.

Fuse Replacement

Replace the fuse with a fast-acting type of the specified rating.

Notes on Accessories

Case Lid

Instructions for fitting the case lid under the housing case.

How to fit Neck Strap & Test Probe Pouch

Guidance on attaching the neck strap and test probe pouch.

Cleaning of the Instrument

Service