FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualified in hot water boiler installation and maintenance. Improper installation and/or operation could
create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death.
Improper installation and/or operation will void the warranty.
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a nearby phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or gas
supplier.
H0117400E
Installation and Operation
Instructions for
Mighty Therm
Hydronic Boilers
Models HH and PH
Sizes 500-1825
These instructions are to be stored in the pocket provided on the boiler
Installation and Operation Instructions Document 1049E
Question and Answer IconNeed help?

Do you have a question about the Laars Mighty Therm HH 1200 and is the answer not in the manual?

Summary

Installation

2 A. Boiler Placement

Specifies clearances, surface requirements, and location considerations for boiler installation.

2 B-2. Venting

Details requirements for flue outlet connection, vent pipe installation, and draft diverters.

2 D. Gas Supply and Piping

Covers gas type verification, piping requirements, and sediment trap installation.

2 E. Electrical Wiring

Addresses electrical grounding requirements and wiring connections according to codes.

Operation

3 B. Initial Start-Up

Covers safe lighting procedures, gas valve checks, and pilot flame response time verification.

Maintenance

Troubleshooting and Analysis of Service Problems

3. BOILER WILL NOT FIRE.

Lists possible causes and solutions for the boiler failing to ignite or start, covering power, gas, and controls.

6. SOOT IN FLUEWAYS OR IN TUBES, OR NOXIOUS FUMES INDICATIVE OF BAD COMBUSTION.

Details issues related to poor combustion, such as inadequate air supply or venting problems.

Laars Mighty Therm HH 1200 Specifications

General IconGeneral
ModelMighty Therm HH 1200
Input BTU/hr1, 200, 000
Fuel TypeNatural Gas or Propane
Operating Pressure30 psi
TypeHydronic Boiler