If the amplifier is driven very hard into a low impedance load, the cooling fans will run at high speed. If
the causing conditions continue, the “Temp” temperature indicator(s) will illuminate indicating that the
amplifier is about to go into thermal shutdown.
After approximately five seconds the amplifier will go into thermal protection by muting the input signal.
After another 15-20 seconds the amplifier should have cooled down enough for the amplifier to come out
of shutdown and operate as normal. If the load conditions remain unchanged, the thermal protection will
be reinitiated accordingly. Thermal protection starts, if the Intercooler
®
heatsink reaches a temperature
above 90
°
C.
VKNKP= sec=éêçíÉÅíáçå=
If a signal above 12kHz is detected at the amplifier outputs for more than five seconds at full output
power, the VHF protection mutes the input signal. This is indicated by the LED’s on the front panel
labeled Protect. After five seconds the outputs will un-mute and return to normal operation, unless the
output signal has remained unchanged, in which case the VHF protection will re-initiate.
VKNKQ= pÜçêí=ÅáêÅìáí=éêçíÉÅíáçå=
All Lab.gruppen amplifiers are completely short circuit protected. The protection circuitry permits very
high peak currents, but still holds the output devices within the safe operation levels. If a short circuit
remains to be present, the channel effected will eventually go into thermal protect cycle until the short
circuit has been removed.
VKNKR= ^`=ã~áåë=îçäí~ÖÉ=éêçíÉÅíáçå=
If the AC mains voltage is lower or higher than the allowed operational voltage (over- or under-
voltage), the power supply will automatically shut down. Once the mains voltage is above the minimum
start voltage and below its maximum operating voltage the amplifier will restart.
It takes a couple of seconds to self-check (this is known as the "soft start" or "slow start" sequence), the
gain will slowly and gradually be increased back to the previously set level, and the fans will first blow at
high speed before going into "idle". The two green ”ON” LED’s indicate that the power supply is
operating properly.
VKNKS= a`=éêçíÉÅíáçå=
There are two types of DC protection:
Fuses on the supply branches of each channel.
A DC crowbar protection that shorts the output if more than 10 volts DC are being detected on the
outputs.
Either of these protections comes into effect once DC voltage is being detected, independently for both
channels.
i~ÄKÖêìééÉå== = = = = ====================== ========================NQ
rëÉê=j~åì~ä===Ñm=OOMM======sÉêëáçå=MKV========OMMPJNMJMT=

Other manuals for Lab.gruppen FP 2200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen FP 2200 and is the answer not in the manual?

Lab.gruppen FP 2200 Specifications

Power Output IconPower Output
max output power at 8 Ω per channel (EIA)350 W
max output power at 8 Ω per channel (FTC)340 W
max output power at 4 Ω per channel (EIA)650 W
max output power at 4 Ω per channel (FTC)630 W
max output power at 2 Ω per channel (EIA)1100 W, 1175 W
max output power at 2 Ω per channel (FTC)950 W
max output power at 8 Ω bridged (EIA)1400 W
max output power at 8 Ω bridged (FTC)1300 W
max output power at 4 Ω bridged (EIA)2200 W
max output power at 4 Ω bridged (FTC)1900 W
Voltage Specifications IconVoltage Specifications
max output voltage at 8 ohms load, MLS @ 0 dB53 Vrms
peak voltage, no load77 V
slew rate40 V/µs
Distortion and Noise IconDistortion and Noise
THD 20 Hz–20 kHz and 1 W to full power0.03 %
THD @ 1 kHz and –1 dB under clip0.006 %
DIM 30 at –3 dB under clip0.008 %
hum and noise<–110 dB
channel separation @10kHz70 dB
Input Specifications IconInput Specifications
gain, selectable20, 23, 26, 29, 32, 35, 38, 41 dB
impedance20 kohm
common mode rejection50 dB
Power Requirements IconPower Requirements
operation voltage (230 V version)130 V–265 V AC
operation voltage (115 V version)65 V–135 V AC
minimum start voltage (230 V version)175 V
minimum start voltage (115 V version)85 V AC
full output power at 4 ohms (230 V version)180 V–265 V AC
full output power at 4 ohms (115 V version)90 V–130 V AC
peak inrush current (soft start limited)5 A
Current Draw IconCurrent Draw
quiescent power (no load) (230 V version)0.9 Arms
quiescent power (no load) (115 V version)1.8 Arms
1/8 of full power (–9 dB) (230 V version)5 Arms
1/8 of full power (–9 dB) (115 V version)10 Arms
1/3 of full power (–5 dB) (230 V version)8 Arms
1/3 of full power (–5 dB) (115 V version)16 Arms
at full power (0 dB) @1 kHz 1% THD (230 V version)14 Arms
at full power (0 dB) @1 kHz 1% THD (115 V version)28 Arms
Weight and Dimensions IconWeight and Dimensions
net dimensions (mm)483 W ✕ 88 H ✕ 287 D
net dimensions (inch)19˝ W ✕ 3.5˝ H ✕ 11.3˝ D
shipping dimensions (mm)560 W ✕ 180 H ✕ 500 D
shipping dimensions (inch)22˝ W ✕ 7.1˝ H ✕ 19.7˝ D
net weight7.9 kg (17 lbs)
shipping weight9.6 kg (21.2 lbs)