12 WARRANTY...............................................................................................................................17
O= =^mmols^ip=
This equipment conforms to the requirements of the EMC directive 89/336/EEC, amended
by 92/31/EEC and 93/68/EEC and the requirements of the Low Voltage Directive
73/23/EEC, amended by 93/68/EEC.
Standards applied EMC Emission EN55103-1, E3
EMC Immunity EN55103-2, E3, with S/N below 1% at normal operation level.
Electrical Safety EN60065, Class I
This equipment is tested and approved according to the
U.S. safety standard ANSI/ UL 6500 and Canadian
safety standard CSA E60065-00. ETL made the tests
and they are a Nationally Recognized Testing
Laboratory (NRTL).
P= t^okfkdp=
PKN= bñéä~å~íáçå=çÑ=Öê~éÜáÅ~ä=ëóãÄçäë=
The lightning symbol within a triangle is
intended to alert the user to the
presence of un-insulated “dangerous voltage”
within the amplifier’s enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to humans.
The exclamation point within a triangle is
intended to alert the user to presence of
important operating and service instructions in
the literature accompanying the product.
!
PKO= t^okfkd==
To reduce risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
PKP= `^rqflk=
To reduce the risk of fire or electric shock, do
not remove screws. No user-serviceable parts
inside. Refer servicing to qualified service
personnel.
PKQ= fãéçêí~åí=p~ÑÉíó=fåëíêìÅíáçåë=
Before using your amplifier, be sure to carefully read the applicable items of these operating
instructions and the safety suggestions
1. Keep this manual for future reference.
2. Heed all warnings.
3. Follow all instructions.
4. Do not use this unit near water. Do not spill water or other liquids into or on the unit. Do not
operate the amplifier while wet or standing in liquid.
5. Clean only with dry cloth.
6. Do not block the air intake or exhaust ports. Install the unit in accordance with the instructions.
!
7. Do not operate the amplifier near heat producing devices such as radiators, heat registers, stoves
or other apparatus that produce heat.
8. Always operate the unit with the chassis ground wire connected to the electrical safety earth. Do
not defeat the safety purpose of a grounding-type plug. A grounding type plug has two pins and
a third grounding prong. The third prong is provided for your safety. If the provided plug does
not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
9. Connect only to AC power outlets rated 200-240V, 50-60Hz.
i~ÄKÖêìééÉå== = = = = ====================== ========================O
rëÉê=j~åì~ä===Ñm=OOMM======sÉêëáçå=MKV========OMMPJNMJMT=

Other manuals for Lab.gruppen FP 2200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen FP 2200 and is the answer not in the manual?

Lab.gruppen FP 2200 Specifications

Power Output IconPower Output
max output power at 8 Ω per channel (EIA)350 W
max output power at 8 Ω per channel (FTC)340 W
max output power at 4 Ω per channel (EIA)650 W
max output power at 4 Ω per channel (FTC)630 W
max output power at 2 Ω per channel (EIA)1100 W, 1175 W
max output power at 2 Ω per channel (FTC)950 W
max output power at 8 Ω bridged (EIA)1400 W
max output power at 8 Ω bridged (FTC)1300 W
max output power at 4 Ω bridged (EIA)2200 W
max output power at 4 Ω bridged (FTC)1900 W
Voltage Specifications IconVoltage Specifications
max output voltage at 8 ohms load, MLS @ 0 dB53 Vrms
peak voltage, no load77 V
slew rate40 V/µs
Distortion and Noise IconDistortion and Noise
THD 20 Hz–20 kHz and 1 W to full power0.03 %
THD @ 1 kHz and –1 dB under clip0.006 %
DIM 30 at –3 dB under clip0.008 %
hum and noise<–110 dB
channel separation @10kHz70 dB
Input Specifications IconInput Specifications
gain, selectable20, 23, 26, 29, 32, 35, 38, 41 dB
impedance20 kohm
common mode rejection50 dB
Power Requirements IconPower Requirements
operation voltage (230 V version)130 V–265 V AC
operation voltage (115 V version)65 V–135 V AC
minimum start voltage (230 V version)175 V
minimum start voltage (115 V version)85 V AC
full output power at 4 ohms (230 V version)180 V–265 V AC
full output power at 4 ohms (115 V version)90 V–130 V AC
peak inrush current (soft start limited)5 A
Current Draw IconCurrent Draw
quiescent power (no load) (230 V version)0.9 Arms
quiescent power (no load) (115 V version)1.8 Arms
1/8 of full power (–9 dB) (230 V version)5 Arms
1/8 of full power (–9 dB) (115 V version)10 Arms
1/3 of full power (–5 dB) (230 V version)8 Arms
1/3 of full power (–5 dB) (115 V version)16 Arms
at full power (0 dB) @1 kHz 1% THD (230 V version)14 Arms
at full power (0 dB) @1 kHz 1% THD (115 V version)28 Arms
Weight and Dimensions IconWeight and Dimensions
net dimensions (mm)483 W ✕ 88 H ✕ 287 D
net dimensions (inch)19˝ W ✕ 3.5˝ H ✕ 11.3˝ D
shipping dimensions (mm)560 W ✕ 180 H ✕ 500 D
shipping dimensions (inch)22˝ W ✕ 7.1˝ H ✕ 19.7˝ D
net weight7.9 kg (17 lbs)
shipping weight9.6 kg (21.2 lbs)