ALARMS
The3138NVGAcanbeequippedwitheitherthestandardonelight,twolights,orthethree
light"stacklight"alarmoutputconfiguration.Thestandardalarmstrobelightwillflashquickly
orslowlyifoneoffivealarmconditionsoccurs.Ifaconditionthatcausesaslowflashanda
conditionthatcausesafastflashoccursimultaneously,thestrobewillflashquickly.
Inathreestacklightsystem,thegreenlightwillbeonconstantlywithnoerrorcondition,and
flashslowlyduringawarningcondition.Thegreenlightwillgooutaltogetherduringafault
condition.
3138NGAALARM
CONDITIONS AND
RESPONSES
ALARM ONELIGHT TWOLIGHTCE TWOLIGHT THREELIGHT
CONDITION (YELLOW) U.S. CE
LowLabel SlowFlash Yellow Yellow Yellow/Slow
 Green
OutofLabel FastFlash Blue/Yellow Red/Yellow Blue
LowRibbon SlowFlash  Yellow Yellow Yellow/Slow
 Green
OutofRibbon FastFlash Blue/Yellow Red/Yellow Blue
EndofWeborFastFlash Blue/Yellow Red/Yellow Blue
WebBreak
TheOutofLabel,LowRibbon,andtheOutofRibbonalarmsmonitortheprinteralarmstatus.
Refertotheprintermanualifthesealarmsneedadjustment.
TheLowLabelalarmmonitorsthesupplyoflabelsontheapplicatorunwinds.Thealarmtrip
pointisadjustableandmayrequireadjustment.Refer
totheLowLabelDetectorSectionfor
adjustmentinstructions.