LAGOON 380
SAFETY
98
Other locations are possible, the extinguishers shall be less than 5 m from all the berths.
An extinguisher shall be compulsorily set less than 2 m away from the extinguisher aperture.
An extinguisher or a fire blanket (ISO ISO 1869) shall be set less than 2 m from any flame appliance.
An extinguisher shall be less than 1 m from the steering station.
All extinguishers should be easily accessible and should be able to be reached rapidly for use,maintenance or repair without having to use
tools or to remove any part of the boat including drawers and shelves.
The positions are the same for the other layout version.
Portable fire extinguishers
(not supplied)
Emergency exit
Extinguisher aperture of the
engine compartment
EXTINGUISHER ACCESS HOLE
PLACE OF EMERGENCY EXITS AND PORTABLE FIRE EXTINGUISHERS (not supplied)