• USE OF THE WASHBASINS AND SHOWERS
Waste water from the shower room is evacuated to the sump by an
automatic start pump (located under the trough).
In the event of a breakdown in the automatic system,use the switch
to action the pump manually (located next to the pump).
Clean filters and trays regularly.
• RESPECT OF THE ENVIRONMENT
- Remain informed of local regulations concerning the environment
and follow the codes of best practice.
- Do not drain the contents of the sewage tank near the coast or in
zones where it is forbidden.
- Make use of the port or marina pump facilities to drain the sewage
tank before leaving port.
- Find out the international regulations against marine pollution
(Marpol) and follow them as far as possible.
• USE OF THE MARINE HEADS
Before you use the heads, check that the water intake valve and
draining valve are open.
To empty the bowl:
- Set the control lever of the pump slantwise (FLUSH).
- Operate the pump.
To dry the bowl:
- Set the lever back vertical (DRY).
- Operate the pump.
• ELECTRIC TOILET (OPTIONAL)
Ensure the valve opening.
The electric toilets are activated by the switch on the electrical pa-
nel.
Lay out of - Fuses: Starboard aft cabin.
For use and maintenance of the material consult the manufacturer
instructions.
In order to avoid clogging the heads, use absorbent paper exclusi-
vely.
Schedule a regular rinsing through of the heads with fresh water.
Close the valves after each use (in particular when the boat is unat-
tended).
Sanitary equipment
RECOMMENDATION
When you are in a marina, use the club-house sanitary faci-
lities (if there are).
Since it is prohibited to discharge the waste waters in some
marinas or countries, you shall use a waste holding tank
(WHT).