Rev. 04 - 02/2024
18
AVVERTENZE DI SICUREZZA - SAFETY INSTRUCTION - CONSIGNES DE SÉCURITÉ
SICHERHEITSHINWEISE - ADVERTENCIAS DE SEGURIDAD - УКАЗАНИЯ ПО БЕЗОПАСНОСТИ
ing, when applicable, FLAMMABLE REFRIGERANTS. In addion, a set of calibrated weighing scales
shall be available and in good working order. Hoses shall be complete with leak-free disconnect
couplings and in good condion. Before using the recovery machine, check that it is in sasfactory
working order, has been properly maintained and that any associated electrical components are
sealed to prevent ignion in the event of a refrigerant release. Consult manufacturer if in doubt.
• The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cyl-
inder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and
especially not in cylinders.
• If compressors or compressor oils are to be removed, ensure that they have been evacuated to
an acceptable level to make certain that FLAMMABLE REFRIGERANT does not remain within the
lubricant. The evacuaon process shall be carried out prior to returning the compressor to the
suppliers. Only electric heang to the compressor body shall be employed to accelerate this pro-
cess. When oil is drained from a system, it shall be carried out safely.
RESIDUAL RISKS
• The correct design of the equipment and the installaon of adequate protecve devices do not completely
eliminate the risks for the operator. This manual contains the list of personal protecve equipment (PPE)
that the employee must use. Sucient space is provided during the installaon phases of the equipment to
limit the risks. To maintain these condions, the areas surrounding the equipment must be kept clean, dry,
well-lit and free from obstacles. Below is a list of the residual risks that remain on the machine.
RESIDUAL RISK DESCRIPTION
Slipping or falling
The operator can slip due to the presence of water, oil or dirt on the oor.
Burns or
abrasion
The user intenonally or unintenonally touches some of the components
inside the equipment (e.g. cold trays, ns and cooling circuit tubes) without
using protecve gloves.
Electrocuon
Contact with live electrical parts during maintenance operaons carried out
without disconnecng the power supply
Falling
The operator intervenes on the equipment using unsuitable systems to access
the upper part.
Injuries
Specialist personnel may not properly secure the upper control console. The
laer could detach and fall o.
Overturning
While moving the equipment and packaging using liing and/or handling
systems that are unsuitable or with the load unbalanced
Refrigerant gas
Inhalaon of refrigerant gas. The pe of refrigerant is shown on the
equipment technical specicaons plate
EMERGENCY SITUATIONS
CAUTION
In the event of re, do not use water, keep CO
2
(carbon dioxide) exnguishers to
hand and cool the motor compartment as quickly as possible.
IN CASE OF EQUIPMENT MALFUNCTIONING...
CAUTION
If the equipment does not work or you noce funconal or structural changes,
disconnect it from all the mains supplies and contact a service centre authorised
by the manufacturer, without aempng to repair it yourself.
CAUTION
Be sure to use original spare parts. The manufacturer declines any responsibili for
the use of non-original spare parts.
• To ensure that the equipment is maintained in perfect condions for use and safe, we recommend
that a service and inspecon be carried out by an authorised service centre at least once a year.