  • C
    Christopher JamesAug 20, 2025
    Why is there no welding current in my Lampert PUK04?
    • J
      Jasmine HardinAug 20, 2025
      The absence of welding current in your Lampert Welding System could stem from several factors. It may be due to an interrupted mains cable, so check the cable and voltage. The device fuse might be blown and need replacing with an identical one. Welding cable connections could be interrupted, so inspect those connections. There might be poor or zero contact with the workpiece; ensure a solid connection, fastening contact clamps directly to the workpiece. A leakage current fault could also be the cause; try switching the device off and on again. If the issue persists, arrange for servicing.
  • J
    Jasmine JonesAug 22, 2025
    What to do if my Lampert PUK04 Welding System keeps blowing the mains fuse?
    • M
      Michelle FloresAug 22, 2025
      If the mains fuse blows or the automatic circuit breaker trips with your Lampert Welding System, it could be due to the mains not being sufficiently fused or an incorrect automatic circuit breaker being used. Ensure the mains are properly fused. If the mains protection trips during idling, arrange for servicing of the device.
  • N
    Natalie RichmondAug 25, 2025
    Why does the Tungsten electrode weld to the workpiece in my Lampert Welding System?
    • E
      Elizabeth WrightAug 25, 2025
      The Tungsten electrode welding to the workpiece in your Lampert Welding System is caused by excessive pressure of the electrodes on the workpiece. Touch workpiece with extremely light pressure.
  • D
    David WareAug 26, 2025
    Why does my Lampert Welding System have poor welding characteristics?
    • T
      Troy NguyenAug 26, 2025
      Poor welding characteristics in your Lampert Welding System can be due to using the incorrect shielding gas. Use inert shielding gas (Argon 4.6).
  • P
    Pamela LopezAug 28, 2025
    Why does the Tungsten electrode melt off immediately in my Lampert Welding System?
    • Q
      qsmithAug 28, 2025
      If the tungsten electrode melts off immediately in your Lampert Welding System, it may be because the electrode is sharpened too steeply. Use the recommended angle of grinding (approx. 15°).
  • S
    Shannon JenningsAug 30, 2025
    Why does my Lampert PUK04 Welding System cause oxidation and rusting?
    • J
      Jennifer AllenAug 30, 2025
      Oxidation and rusting with your Lampert Welding System may be due to excessive gas pressure. Reduce the flow rate; approximately 2 l/min is recommended.
  • D
    Denise CookSep 1, 2025
    What causes severe oxidation of the welding points in my Lampert PUK04 Welding System?
    • E
      Elizabeth WilsonSep 1, 2025
      Severe oxidation of the welding points when using your Lampert Welding System is caused by using incorrect shielding gas. Use inert shielding gas (Argon 4.6).
  • K
    kathleensimpsonSep 2, 2025
    What causes Tungsten inclusions in base material when using Lampert Welding System?
    • J
      Jennifer LynchSep 2, 2025
      Tungsten inclusions in the base material when using your Lampert Welding System are caused by excessive pressure of the electrodes on the workpiece. Touch workpiece with extremely light pressure.
  • A
    andrewjohnsonSep 4, 2025
    What to do if my Lampert PUK04 Welding System starts welding immediately upon touching the workpiece?
    • K
      Kayla ColeSep 4, 2025
      If your Lampert Welding System begins to weld immediately when touching the workpiece (without gas pre-flow), immediately shut down the device and arrange for servicing, as this indicates a fault.
  • T
    tracywangSep 6, 2025
    How to fix poor ignition characteristics in my Lampert Welding System?
    • N
      Natalie Jordan DDSSep 6, 2025
      Poor ignition characteristics in your Lampert Welding System can be caused by the electrode being clamped loosely in the hand piece. Tighten the clamping nut in the handpiece by hand, however, tighten firmly.

Summary

Safety Instructions

General Safety Requirements

General safety requirements and precautions for device operation.

Hazards and Personal Body Protection

Personal protective equipment and potential hazards during welding operations.

Setup and Installation

Set-up of the Device

Instructions for positioning and installing the welding device.

Inserting Electrodes into Welding Hand Piece

Steps for inserting and adjusting welding electrodes in the handpiece.

Commissioning

Switching On the Device

Step-by-step instructions for safely powering on the PUK04.

Welding Parameters and Program Saving

Selection of Welding Parameters

Guidance on choosing power and pulse duration for welding.

Welding Instructions

Welding Instructions

Step-by-step guide on performing the welding process.

Care of System Components

Troubleshooting

Welding Device Troubleshooting

Common faults, causes, and remedies for the welding device.

Microscope Troubleshooting

Troubleshooting common problems with the welding microscope.

Spare Parts List

Lampert PUK04 Specifications

General IconGeneral
BrandLampert
ModelPUK04
CategoryWelding System
LanguageEnglish

Related product manuals