18
Landmann
Connecting and disconnecting the gas cylinder
Parts and tools needed
17 mm spanner (open-ended spanner SW 17)
Gas cylinder
Standard camping gas cylinder with 5 or 11 kg liquid gas (e.g. grey camping propane gas cylinder).
These are available at DIY shops or liquid gas suppliers.
Leak detector
You can locate any leaks in the gas system using a leak detector. This can be purchased at DIY
shops or liquid gas suppliers. Please follow the operating instructions of the leak detector.
The following parts are included in delivery. They comply with the standards applicable in the country
to which they have been supplied by LANDMANN.
Pressure regulator
Preset and
-approved pressure regulator, max. 1.5 kg/h, operating pressure 30 mbar, suitable
for the gas cylinder used.
Gas hose
-approved hose of sufficient length, allowing installation without any kinks.
Connecting the Gas Cylinder
Danger "Ignition of escaping gas"
Liquid gas is highly flammable and explosive.
Possible consequences:
Serious personal injury or damage to property if escaping gas ignites in
an environment in which it is not controlled.
Safety precautions:
When connecting the gas cylinder ensure that there are no sources of
ignition within a 5 m radius.
Take special care not to light any naked flames, do not smoke or switch
on electric appliances (devices, lights, door bells), etc. (sparkover possi-
ble).
If necessary, replace the hose in order to comply with the corresponding
national requirements.
1. Select a suitable place to set up the cooker. Make sure that ...
no flammable materials or substances are in close proximity to the cooker. Minimum distance
to flammable materials or substances: 2m above and 1m to the side; distance to flame resi-
stant materials or substances - min 0.25 m.
the cooker is positioned firmly on a flat, sufficiently large surface area. It must not be moved
during operation.