INSTRUCTIONS MANUAL 
-18- 
     
The machine will now fill the machine bottle with the preset quantity ± 500g. When the quantity 
minus 500 grams is reached, the machine will stop and display: 
     
Close the bottle tap and press START. The machine will stop automatically after having 
recovered the residual refrigerant from the hoses. Close the high-pressure tap. Disconnect the 
external bottle. Switch the machine off. 
VACUUM PUMP 
Perform the operations listed below on a routine basis in order to ensure good operation of the 
vacuum pump: 
M1) Oil top-up. 
M2) Oil change. 
When topping-up or replacing the pump oil, use only the oil recommended by the 
manufacturer. Contact your retailer for information concerning the correct type of oil. 
M.1) Oil top-up 
This operation must be performed when the level of the oil falls to less than half on the indicator 
(4) (refer to Figure 10). NOTE: in order to correctly check the oil level, run the pump for at least 
1 minute (running a vacuum procedure in the hose for 1 minute) so that the oil fluidifies. Check 
the oil level when the pump stops. To refill the oil, perform the steps listed below in the order 
given. Disconnect the MACHINE from the mains supply. Locate the oil cap (2) and screw it 
completely off. The oil must be added through the hole in which the oil cap was lodged (2). Add 
oil a little at a time, waiting for the level to rise before each successive addition, until the oil level 
is about ½ cm above the red mark on the indicator (4). Replace the oil cap (2) and tighten 
down. 
M.2) Oil change 
The vacuum pump oil must be replaced every 150 working hours and in any case every time 
the refrigerant filters are replaced. The oil must also be replaced whenever it changes color 
due to absorption of humidity. Before beginning the oil change procedure, procure a container 
of at least 500 cc capacity in which to collect the used oil. The pump contains about 500 cc of 
oil. Use only the oils recommended by the manufacturer (consult your retailer). 
1)  Disconnect the machine from the mains supply. 
2)  Unscrew the filling cap 2 (refer to Fig. 10). 
3)  Unscrew the drain cap 3. 
4)  Allow all the oil to run out into a disposal container (with height < 10 cm). 
5)  Close the drain cap 3. 
6)  Pour in new oil through the filling hole, opened previously, until the level rises to the 
midpoint on the indicator 4. 
7)  Replace the oil cap 2 and tighten. 
REPLACING THE DRYER FILTERS 
Replace the filters whenever the machine gives the service alarm during the first ten seconds 
of operation or whenever the humidity gage (“c” in Fig. 6) signals the presence of humidity in 
FILLING BOTTLE 
Close external  
bottle tap  
Press Start 
 
FILLING BOTTLE 
         0 g