Use the arrow keys and the number pad to change the Max, Min, and Tare values. Then select
PREVIOUS MENU and press ENTER.
Press START to confirm saving the data or STOP to exit without saving.
CALIBRATING THE OIL SCALE
Access the CALIBRATION MENU as explained above.
The following screen will be displayed:
Select OIL SCALE and press the ENTER key. The following screen will be displayed:
Empty the oil containers. Replace the empty containers in their lodgings, taking care not to
exert pressure on the scale, and press START. The following screen will be displayed:
Fill the new oil container with a known volume of new oil (from 100 a 250 cc measured on the
container measure marks). Replace the container in its lodging, taking care not to exert
pressure on the scale. Use keys 0 through 9 to type in the known oil volume, in cc, and press
START. Select “PREVIOUS MENU” to exit the CALIBRATION MENU. Press START to save
the data. Switch off the machine and disconnect it from the electrical supply.
BOTTLE TEMPERATURE
NOTE: A digital thermometer is required for bottle temperature sensor calibration. Check that
the bottle temperature probe is disconnected from the bottle and so capable of reading the
ambient temperature.
Enter the CALIBRATION MENU as explained above.
The following will be displayed:
<BOTTLE SCALE >
OIL SCALE
BOTTLE TEMPERATURE
SAVE DATA:
Press START.
To exit:
press STOP
Max xxxxx g
Min xxxxx g
Tare xxxxx g
PREVIOUS MENU
ZERO LEVEL
Empty oil containers
Levels xxxxx
Press START
REFERENCE VALUE
xxxx cc
Levels xxxx
Press START