Use the arrow keys and the number pad to change the Max, Min, and Tare values. Then select 
PREVIOUS MENU and press ENTER.  
     
Press START to confirm saving the data or STOP to exit without saving.  
CALIBRATING THE OIL SCALE  
Access the CALIBRATION MENU as explained above. 
The following screen will be displayed: 
     
Select OIL SCALE and press the ENTER key. The following screen will be displayed: 
     
Empty the oil containers. Replace the empty containers in their lodgings, taking care not to 
exert pressure on the scale, and press START. The following screen will be displayed: 
     
Fill the new oil container with a known volume of new oil (from 100 a 250 cc measured on the 
container measure marks). Replace the container in its lodging, taking care not to exert 
pressure on the scale.  Use keys 0 through 9 to type in the known oil volume, in cc, and press 
START. Select “PREVIOUS MENU” to exit the CALIBRATION MENU. Press START to save 
the data. Switch off the machine and disconnect it from the electrical supply.  
BOTTLE TEMPERATURE 
NOTE: A digital thermometer is required for bottle temperature sensor calibration. Check that 
the bottle temperature probe is disconnected from the bottle and so capable of reading the 
ambient temperature. 
Enter the CALIBRATION MENU as explained above. 
The following will be displayed: 
<BOTTLE SCALE > 
OIL SCALE 
BOTTLE TEMPERATURE 
 
SAVE DATA: 
Press START. 
To exit: 
press STOP 
 