Page 43
For HELP, call In-Touch at 866.461.3123
CODE DESCRIPTION
CORRECTIVE ACTION
SP in Input voltage
low
Check incoming voltage to GFCI
Check incoming voltage to spa pack
SP OH Water
temperature
overheat
Open the spa cover and add cold water
through the filter
SP Ot Internal
overheat
Open the access panel to the spa pack
(below the control panel) and allow two
hours to cool down
Reset GFCI breaker
Low-Level Settings
The spa pack – located inside the spa below the topside control panel –
has a service panel used to set your spa’s low-level programming.
During troubleshooting, you may need to check or reset these settings.
Resetting the Spa Pack
To reset the spa pack, press the Select button twice.
Resetting the Low-Level and Breaker Setting
To reset the low-level setting (LL), press and hold down
the Select button for 5 seconds. Use the Change button
to set LL even if it is the present value. Press Select to
save (breaker settings appear next).
Model
Limited
LL
05
After setting LL, the breaker current setting (Br) appears.
Press the Change button to select the appropriate value
for your configuration and then press Select to save.
Configuration
240V 60Hz
240V 50Hz 1φ
240V 50Hz 2φ
240V 50Hz 3φ
Br
40
1P
2P
3P
Figure 29 - Spa Pack Callouts
IR Receiver
Topside
Heater 2
Heater 1
Pump 1
Pump 2
Pump 3
Blower
Circulation
Pump
Ozonator
Stereo
Light
Interface
Change
Select