EasyManua.ls Logo

LDG FTL-Meter - Transmit Parameter Selection; Finish Setup

LDG FTL-Meter
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PAGE 9
Transmit Parameter Selection
With the transceiver still in menu mode, turn the SELECT knob until menu item #61, “MTR ATX
SEL” is displayed. This menu selects what value is displayed on the meter during transmit operation. Rotate
the main tuning knob to select one of the following 6 options:
Menu #61 MTR ATX
SEL
Meaning
OFF
No meter display when receiving
VLT
Displays incoming power supply voltage
SWR
Standing Wave Ratio (SWR)
MOD
Modulation percentage / deviation level
ALC
Automatic Level Control voltage
PWR
Transmit power output
Select the desired function to display.
Finish Setup
When finished with selecting receive and transmit parameters, press and hold the FUNC button to
return the radio to normal operation. If, at some point, it is desired to display different parameters, the
parameter selection process can be repeated. Just select menu item 60 for the receive parameter, or menu
item 61 for the transmit parameter.