Installation and Operation Manual
SPEEDMASTER
®
SM SERIES SUB-MICRO INVERTERS
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Questions and Answers

  • J
    John MorganAug 15, 2025
    Why does my Leeson SPEEDMASTER SM display a Current Overload Fault?
    • M
      Mary ToddAug 15, 2025
      A Current Overload Fault in your Leeson Inverter typically means that the VFD is undersized for the application or there's a mechanical problem with the driven equipment.
  • R
    Richard FoxAug 18, 2025
    What causes a High Temperature Fault on a Leeson SPEEDMASTER SM?
    • H
      Heather DouglasAug 18, 2025
      A High Temperature Fault can be triggered if the ambient temperature is too high, or if the cooling fan has failed (if the inverter is equipped with one).
  • J
    Jeffrey TurnerAug 21, 2025
    What does it mean when my Leeson SPEEDMASTER SM Inverter shows a Remote Keypad Fault?
    • G
      gomezelaineAug 21, 2025
      A Remote Keypad Fault indicates that the communication link between the drive and the optional Remote Keypad has been lost. Check the wiring and look for any noise that might be interfering with the signal.
  • C
    Christopher RamseyAug 25, 2025
    What causes an Incompatibility Fault in a Leeson SPEEDMASTER SM?
    • S
      Stephen ThomasAug 25, 2025
      An Incompatibility Fault occurs when an EPM with an incompatible parameter version has been installed. You can either remove the EPM or perform a factory reset (Parameter 48) to align the parameter version of the EPM with that of the drive.
  • K
    Katie MccormickAug 27, 2025
    How to fix a Control Fault on a Leeson SPEEDMASTER SM?
    • D
      Darlene GillAug 28, 2025
      A Control Fault happens when a blank EPM, or an EPM with corrupted data, is installed. To resolve this, perform a factory reset using Parameter 48 - PROGRAM SELECTION.
  • S
    shelleyhunterAug 30, 2025
    Why does my Leeson Inverter show an External Fault?
    • C
      Christopher ThomasAug 31, 2025
      An External Fault occurs if one of the TB-13 terminals is set as an External Fault input and that terminal is open with respect to TB-11. Refer to Parameters 10, 11 and 12 for configuration details.
  • P
    pamela94Sep 2, 2025
    Why does my Leeson Inverter show a Low DC Bus Voltage Fault?
    • V
      villanuevaadamSep 2, 2025
      A Low DC Bus Voltage Fault indicates that the line voltage is too low.
  • K
    Kelly NguyenSep 5, 2025
    What to do if Leeson Inverter shows a Start Fault?
    • D
      danielhernandezSep 5, 2025
      A Start Fault means a start command was present when the drive was powered up. If START METHOD is set to NORMAL, wait 2 seconds after power-up to apply the Start command.
  • R
    richardelliottSep 8, 2025
    What does it mean when my Leeson SPEEDMASTER SM displays a Data Fault?
    • T
      Tamara MitchellSep 8, 2025
      A Data Fault indicates that user data and OEM defaults in the EPM are corrupted.
  • R
    Rhonda SullivanSep 12, 2025
    What causes an EPM Fault on a Leeson SPEEDMASTER SM Inverter?
    • M
      Mrs. Michelle RaySep 12, 2025
      An EPM Fault indicates that the EPM is either missing or damaged.

Summary

Important Safety Notices

Electrical Shock and Operational Hazards

Covers DANGER/WARNING about shock, capacitors, and automatic start.

Environmental and Installation Warnings

Covers adverse environmental conditions and installation requirements.

Cautionary Notes and Personnel Qualifications

Covers radio interference, qualified personnel, and general cautions.

Safety Information

General Safety Guidelines

Operations must be by qualified personnel following safety regulations.

Application as Directed

Drives are for electrical systems/machinery, not appliances; professional use only.

Electrical Connection Safety

Observe regulations, use correct wire size, grounding, and disconnects.

Installation Procedures

Installation After Long Storage

Reforming DC bus capacitors is required after extended storage.

Input AC Power Requirements

Power Wiring Guidelines

Power Wiring Diagram

Visual representation of power connections for the drive.

Control Wiring

Speed Reference Selection and Control

Speed Reference Selection

How to select speed sources like keypad, analog signals, or preset speeds.

Control Wiring Diagrams

Start;Stop Control Methods

Initial Power Up and Motor Rotation Check

Programming the Drive

Parameter Menu and Descriptions

Parameter Menu Overview

Introduction to accessing and navigating the drive's parameter settings.

Core Settings (P01-P06)

Key parameters for basic drive configuration like voltage, start/stop, and speed source.

Troubleshooting Guide

Display Messages and Status

Status and Warning Messages

Lists display codes for various drive statuses and warnings.

Leeson SPEEDMASTER SM Series Specifications

General IconGeneral
EnclosureNEMA 1
Overload Capacity150% for 60 seconds
Output Frequency0-400 Hz
Control MethodV/Hz
CommunicationModbus RTU
Operating Temperature14°F to 104°F (-10°C to 40°C)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overheating