07-01913L F515 6 Legend Brands Products, Inc.
Before each use
Inspect the electrical cord for damage. Look for fray-
ing, cuts, etc. Replace the cord if you find any damage.
Inspect filter. The PHD 200 filter should be replaced
when the accumulation of dust is visible.
Monthly
Clean pump check valve and basin. In normal use,
dust can accumulate and can restrict airflow, reducing
performance and causing the unit to overheat. Clean
when dust accumulation is visible. Remove grills and
cover as shown in Fig. B. Use a vacuum cleaner with a
brush tool and a soft cloth to remove any debris. Take
care not to damage any interior components.
To maintain appearance, wipe interior and exterior sur-
faces with a damp cloth. For deep cleaning and a last-
ing, protective shine, use an automotive interior cleaner.
As Needed
Clean pump check valve and basin. If the unit displays
the message “ER9 PUMP BLOCKED PUMP & HOSE”,
the pump check valve and pump basin may need to be
cleaned. Remove grills and cover as shown in Fig. B.
Remove screws from pump base and lift out pump. Wipe
out pump basin with a damp cloth. Unthread barbed fit-
ting with check valve and rinse fitting and check valve
with clean water. Reinstall barbed fitting into pump. Do
not overtighten. Reinstall pump on base. Reinstall cover
and grills.
Clean coils. With the cover removed, inspect both coils.
If excessive dust and debris is present, vacuum thor-
oughly and/or clean with coil cleaner.
SYSTEM MESSAGES
The Control Panel will display the following messages based on system performance and environmental conditions. User